Combination Meter System: Inspection: Self-Diagnosis
The self-diagnosis (checking of each meter, warning light, indicator, illumination, LCD, buzzer sound) of combination meter can be performed in the following procedure.
- Turn the ignition switch to ON while turning the small light to OFF.
- Step 1) Turn the small light switch to ON within 3 seconds after step 1), then press the ODO/tripmeter knob three times.
- Turn the small light switch to OFF, and press the ODO/trip knob three times.
- Turn the small light switch to ON, and press the ODO/trip knob three times.
NOTE:
- Perform the steps described in 2) and 4) within 10 seconds after the ignition switch is turned to ON.
- When pressing the ODO/trip meter knob four times, the display changes to DTC display mode (ECM, TCM). < Refer to DTC DISPLAY MODE , INSPECTION, COMBINATION METER SYSTEM. >When the self-diagnosis function operates, the warning light, indicator, and LCD display are checked, then every press of the ODO/trip meter knob will initiate the operation checks in the order of meter, illumination and buzzer. < Refer to LIST OF SELF-DIAGNOSIS MODE OPERATION , INSPECTION, COMBINATION METER SYSTEM. > Turn the ignition switch to OFF to cancel the self-diagnosis function.
- When the engine starts during diagnosis, the self-diagnosis function is not cancelled, however, once the vehicle starts driving, the self-diagnosis function is cancelled automatically for safety.