Calibration Of The Backup Camera - AR54.65-P-0022SR
MODEL 453
with CODE 218 (Rear view camera)
MODEL 453
with CODE V52 (Combination code for rear parking aid and reversing camera)
| Check | |||
| Check and correct tire inflation pressure | AP40.15-P-4061C | ||
| Clean | |||
| 2 | Clean lens on reversing camera | ||
| Calibrate | |||
| 3 | Connect diagnostic system and select vehicle using vehicle identification number (VIN) | ||
| AD00.00-P-2000-06SR | |||
| 4 | In the diagnostic system, select the "ZAN-Audio/COMAND display (A40/3)" control unit | ||
| 5 | Mark longitudinal axis of vehicle on bumper at rear | ||
| 6 | Position calibration device (1) behind vehicle as shown | The center lines of the calibration device (1) and vehicle's longitudinal axis must line up and the wheels must make contact with the calibration device (1) as shown. Wrong measurements can occur otherwise. |
|
| Fig 1 | |||
| 7 | Follow diagnostic system instructions | ||
| 8 | Once calibration is over, disconnect the diagnostic system | ||
| AD00.00-P-2000-06SR | |||
| Check | |||
| 9 | Perform function test of reversing camera | If there are problems | |
| ↓ | |||
| Repeat calibration. |