Measure absolute angle at transmission - AR41.10-P-0085-01PA

WARNING: This page does not describe the selected car, but rather 33 other vehicles, including the 2016 Mercedes-Benz E63 S AMG, 2016 Mercedes-Benz E400, 2016 Mercedes-Benz E350, 2016 Mercedes-Benz E300, and 2016 Mercedes-Benz E250. However, it is still accessible from the selected car via links, so may be relevant.

MODEL 171, 172, 203, 204, 207, 209, 211, 212, 215, 218, 219, 220 (except 220.8), 230 

IMPORTANT The vehicle must be on its wheels for the measurement. Start measurement of inclination angle at transmission end. All four angles should be measured in succession without interruption. An angle that has already been measured can be measured a second time if required. To do this, with the Measurement menu displayed, press the "STEP" button repeatedly until the display indicates Ready to measure the relevant angle.

  1. Press "STEP" button on inclinometer.

    IMPORTANT "Inclination angle" "Measurement" is selected.

    Selection menu screen 

    Fig 1: Display - Measurement Selection Menu Screen
    G07009048Courtesy of MERCEDES-BENZ USA

    Measurement - Angle 1, transmission 

  2. Press "STEP" button while main menu is displayed.

    IMPORTANT "Measurement" is selected.

    Fig 2: Display - Measurement Angle 1 Main Menu Screen
    G07009049Courtesy of MERCEDES-BENZ USA

    Main menu screen 

  3. Clean transmission bore and surroundings (arrow) if necessary.
  4. Select suitable adapter for transmission bore.
  5. Remove measuring sleeve socket (020e) from adapter, insert in transmission bore and fix.

    IMPORTANT Do so by turning lower threaded stud (020f) to left and tightening.

    Fig 3: Sleeve Socket And Lower Threaded Stud
    G07070339Courtesy of MERCEDES-BENZ USA

    Shown on model 203, 209 

  6. Screw measuring sleeve adapter (020g) on to measuring sleeve socket and tighten all the way to transmission by hand.

    IMPORTANT Ensure that the measuring sleeve adapter (020g) contacts the surface of the transmission exactly.

    Shown on model 203, 209 

    Fig 4: Measuring Sleeve Adapter
    G07070340Courtesy of MERCEDES-BENZ USA
  7. Mount sensor mount (020c) with the two knurled bolts centrally on the sensor (020a).
    Fig 5: Sensor Mount With Knurled Bolts On Sensor
    G07070341Courtesy of MERCEDES-BENZ USA
  8. Position sensor mount (020c) with sensor (020a) on measuring sleeve adapter (020h) by turning slightly to left/right (magnetic).

    IMPORTANT The spiral cable (020b) of the sensor (020a) must point in the direction of travel for each measurement, otherwise the measurement will be incorrect.

    Shown on model 203, 209 

    Fig 6: Measuring Sleeve Adapter, Spiral Cable, Sensor Mount - Shown On Model 203, 209
    G07565658Courtesy of MERCEDES-BENZ USA

    Show on model 230 

    Fig 7: Positioning Sensor Mount With Sensor On Measuring Sleeve Adapter
    G07070343Courtesy of MERCEDES-BENZ USA

    IMPORTANT The articulation angle meter is ready to take a measurement. The value measured is shown on the display.

  9. Press "SAVE" button.

    IMPORTANT The values are saved.

    Measurement values screen for angle 1: display e.g. 1.92° 

    Fig 8: Display - Measured Values Screen For Angle 1
    G07070328Courtesy of MERCEDES-BENZ USA

    IMPORTANT A confirmation message appears briefly.

    Confirmation screen 

    Fig 9: Display - Confirmation Screen
    G07070329Courtesy of MERCEDES-BENZ USA

    IMPORTANT The display then indicates that the device is ready for the next measurement (angle 2).

  10. Remove sensor (020a) from transmission.
  11. Detach sensor mount (020c) from sensor (020a).
  12. Unscrew measuring sleeve adapter (020g) from measuring sleeve socket (020e).
  13. Unscrew measuring sleeve socket (020e) from transmission bore.

    Ready screen for angle 2 

    Fig 10: Display - Ready Screen For Angle 2
    G07070330Courtesy of MERCEDES-BENZ USA