Measure absolute angle at transmission - AR41.10-P-0085-01PA
MODEL 171, 172, 203, 204, 207, 209, 211, 212, 215, 218, 219, 220 (except 220.8), 230
The vehicle must be on its wheels for the measurement. Start measurement of inclination angle at transmission end. All four angles should be measured in succession without interruption. An angle that has already been measured can be measured a second time if required. To do this, with the Measurement menu displayed, press the "STEP" button repeatedly until the display indicates Ready to measure the relevant angle.
- Press "STEP" button on inclinometer.
"Inclination angle" "Measurement" is selected.
Selection menu screen
Measurement - Angle 1, transmission
- Press "STEP" button while main menu is displayed.
"Measurement" is selected.
Main menu screen
- Clean transmission bore and surroundings (arrow) if necessary.
- Select suitable adapter for transmission bore.
- Remove measuring sleeve socket (020e) from adapter, insert in transmission bore and fix.
Do so by turning lower threaded stud (020f) to left and tightening.
Shown on model 203, 209
- Screw measuring sleeve adapter (020g) on to measuring sleeve socket and tighten all the way to transmission by hand.
Ensure that the measuring sleeve adapter (020g) contacts the surface of the transmission exactly.
Shown on model 203, 209
- Mount sensor mount (020c) with the two knurled bolts centrally on the sensor (020a).
- Position sensor mount (020c) with sensor (020a) on measuring sleeve adapter (020h) by turning slightly to left/right (magnetic).
The spiral cable (020b) of the sensor (020a) must point in the direction of travel for each measurement, otherwise the measurement will be incorrect.
Shown on model 203, 209
Courtesy of MERCEDES-BENZ USA
Show on model 230
Courtesy of MERCEDES-BENZ USA
The articulation angle meter is ready to take a measurement. The value measured is shown on the display.
- Press "SAVE" button.
The values are saved.
Measurement values screen for angle 1: display e.g. 1.92°
A confirmation message appears briefly.
Confirmation screen
The display then indicates that the device is ready for the next measurement (angle 2).
- Remove sensor (020a) from transmission.
- Detach sensor mount (020c) from sensor (020a).
- Unscrew measuring sleeve adapter (020g) from measuring sleeve socket (020e).
- Unscrew measuring sleeve socket (020e) from transmission bore.
Ready screen for angle 2