LEMON Manuals: Even more car manuals for everyone
Home >> Smart >> 2015 >> Fortwo Electric Drive, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 55 (Mixture Formation - 212 Chassis - 02 Of 10) >> Basic Knowledge >> Deceleration fuel shutoff, function >> Deceleration fuel shutoff, function - GF07.10-P-1014MM

Deceleration fuel shutoff, function - GF07.10-P-1014MM

WARNING: This page does not describe the selected car, but rather 33 other vehicles, including the 2016 Mercedes-Benz E63 S AMG, 2016 Mercedes-Benz E400, 2016 Mercedes-Benz E350, 2016 Mercedes-Benz E300, and 2016 Mercedes-Benz E250. However, it is still accessible from the selected car via links, so may be relevant.

ENGINE 276.8 in MODEL 207, 212 as of model year 2014 

ENGINE 276.8 in MODEL 218 as of model year 2015 

ENGINE 276.9 in MODEL 204, 207, 212 (except 212.095), 218 

Function requirements for deceleration fuel shutoff, general points 

Deceleration fuel shutoff, general 

Deceleration fuel shutoff in deceleration mode of the engine has the following tasks:

The ME-SFI [ME] control unit (N3/10) performs a deceleration fuel shutoff dependent on the following sensors and signals:

Deceleration fuel shutoff, function sequence 

In deceleration mode, the ME-SFI [ME] control unit switches off the fuel injectors (Y76) dependent on coolant temperature, engaged gear and engine speed, if the accelerator pedal is not actuated.

The fuel injectors are switched on again when the accelerator pedal is operated. The ME-SFI [ME] control unit also uses the left and right intake camshaft solenoids (Y49/4, Y49/5) and the left and right exhaust camshaft solenoids (Y49/6, Y49/7) to adjust the camshafts to a position with reduced valve overlap. This allows secure combustion without misfires.

After deceleration fuel shutoff, the ME-SFI [ME] control unit enriches the fuel/air mixture by briefly lengthening the injection period in order to relieve the catalytic converters of enriched oxygen. In order to prevent a sudden torque rise when combustion is restarted after a deceleration fuel shutoff, the ME-SFI [ME] control unit briefly shifts the ignition angles of the ignition coils (T1) towards "retard".

Deceleration fuel shutoff is disabled when exhaust temperatures are too high, since the high oxygen content occurring in the exhaust during a deceleration fuel shutoff could cause increased oxidation of carbon monoxide and hydrocarbon (afterburning). The heat so generated can overheat the catalytic converters.

  Electrical function schematic for deceleration fuel shutoff MODEL 204 PE07.10-P-2714-97FAK
MODEL 207 PE07.10-P-2714-97EAH
MODEL 212 PE07.10-P-2714-97DAI
MODEL 218 PE07.10-P-2714-97XAB
  Overview of system components for gasoline injection and ignition system with direct injection ENGINE 276.9 in MODEL 204, 207, 212 (except 212.095), 218 GF07.70-P-9998MM
ENGINE 276.8 in MODEL 207, 212 as of model year 2014
ENGINE 276.8 in MODEL 218 as of model year 2015
GF07.70-P-9998MMP