Home >> Porsche >> 2023 >> Cayenne Base, 4D Utility Coupe >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 23 (27 Starter, Power Supply, Cruise Control E-Hybrid -- 9YA - Cayenne (9YA)) >> WM, 270889 Charging And Discharging Cell Modules >> Charging And Discharging Cell Module

Charging And Discharging Cell Module

WARNING: This page is about a different variant/trim than selected.
Fig 1: Charging And Discharging Cell Module Components Location (VAS 6910)
G15242521Courtesy of PORSCHE CARS NORTH AMERICA, INC.

Component overview - VAS 6910

> VAS 6910 - Module balancer 
Cell module 
> 9900 - PIWIS Tester 3 
WARNING: Incorrect handling of high-voltage components 
  • Electric shock 
  • Risk of short circuit 
  • Risk of fire 
  • Risk of explosion 
    1. → Only appropriately trained and authorised persons are permitted to work on high-voltage vehicles and components.
    2. → Required qualification: High voltage expert.
    3. → Observe national requirements and legislation for this work.
    4. → Always use insulated tools, e.g. > VAS 6883 - Insulated tool set  , when working on these components. Observe general warning notes for working on the high-voltage vehicle electrical system.
    5. > WM, 2X00IN GENERAL WARNING NOTES FOR WORKING ON THE HIGH-VOLTAGE SYSTEM

Information 

Observe the following specifications for all the work described:

These strict specifications apply in particular to:

Consider relevant and qualified sources of information such as local authorities, competent importer, associations and specialised websites for this purpose. Only deliver items to be disposed of to authorised reception points.

These regulations to be complied with have to be checked, observed and, if necessary, documented by the person responsible for the vehicle for all life phases and work.

Information 

Adapt for each new cell module! New cell modules have a state of charge of 30%.

Information 

During the test sequences, green tick marks indicate whether lines were connected correctly. However, these only light up as soon as both ends of the lines have been connected.

Information 

The difference in voltage between the module and the existing modules can be max. 0.3 V.

Information 

The PIWIS Tester  instructions take precedence since the description may be different with later Tester releases.

The procedure described here has been structured in general terms. Different text or additional information may appear on the PIWIS Tester. 

  1. > VAS 6910 - Module balancer  and Tester set up.

    Read and follow the instructions for the module balancer.

  2. Switch on the Tester and select HV system  under Measuring equipment.
  3. Switch on module balancer.
  4. Select Module balancing. 
    1. 4.1  Carry out self-test. 
      1. 4.1.1  Read and follow the instructions on the Tester.
      2. 4.1.2  Perform self-test according to menu guidance.
    2. 4.2 Safety test  must be selected.
      1. 4.2.1  Read and follow the instructions and information on the Tester.
      2. 4.2.2  Perform safety test according to menu guidance.
    3. 4.3  Insert cell module into the module balancer.
    4. 4.4  Check polarity of the cell module.
    5. 4.5  Select Charge/Discharge  on the Tester.
      1. 4.5.1  Enter the necessary data.

        Enter data for selecting the cell module-Module type (e.g. 4M0...), serial number (label on the cell module), setpoint voltage (read out of test log or measure voltage manually on the module).

      2. 4.5.2  Follow the instructions and information on the Tester.
        G15242522Courtesy of PORSCHE CARS NORTH AMERICA, INC.

        Connecting measuring device

      3. 4.5.3  Connect red  > VAS 6910/10-1 - connecting cable-1-  to HV +  for the cell module.
      4. 4.5.4  Connect red  > VAS 6910/10-1 - connecting cable-1-  to HV +  for the > VAS 6910 - module balancer  .
      5. 4.5.5  Connect black  > VAS 6910/10-2 - connecting cable-2-  to HV -  of the cell module.
      6. 4.5.6  Connect black  > VAS 6910/10-2 - connecting cable-2-  to HV -  of the > VAS 6910 - module balancer  .
      7. 4.5.7  Connect cell monitoring cable (CAN) > VAS 6910/12A-3 - connecting line-4-  with the > VAS 6910 - module balancer  .
      8. 4.5.8  Connect electric plug connection -3-  for the cell monitoring cable (CAN) > VAS 6910/12A-3 - connecting cable-4-  to the module.
    6. 4.6  Once the cell module has been charged/discharged successfully, follow the instructions on the Tester.
    7. 4.7  Print the log and file it in the order folder.
  5. Stop Module balancing. 
  6. Remove module balancer and Tester.