LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2022 >> 718 Boxster Base, Standard Trans >> Repair and Diagnosis >> External Pages >> Different car >> Section 4 (5X - Body General) >> WM, 5X00IN22 Working With Body Foam Filler >> Working With Body Foam Filler >> Processing conditions

Processing conditions

WARNING: This page does not describe the selected car, but rather 10 other vehicles, including the 2021 Porsche 718 Cayman, 2021 Porsche 718 Boxster, 2020 Porsche 718 Cayman, 2020 Porsche 718 Boxster, and 2019 Porsche 718 Cayman. However, it is still accessible from the selected car via links, so may be relevant.

During processing, the ambient and material temperature must be at least > Minimum temperature 15°C  and must not exceed a maximum temperature of > Maximum temperature 28°C  .

Higher processing temperatures reduce processing time. Processing can be interrupted briefly for up to 5 minutes.

> Processing time at 15°C 20 min 

> Processing time at 28°C 15 min 

The chemical reaction is essentially complete after approx. 30 minutes. The hardened foam does not swell or shrink.