Removing Change-Over Valve For High-Temperature System (UVW 3)
WARNING: This page is about a different variant/trim than selected.
WARNING:
Hot fluid
- Danger of scalding
→ Avoid contact with hot fluid.
→ Wear personal protective gear.
- Remove change-over valve for high-temperature system -1-
.
- 1.1 Loosen spring band clamps -2- using > VAS 6890 - Spring Band Clamp Pliers and pull off coolant hoses -3- .
- 1.2 Catch escaping coolant and close off line connections using suitable stoppers.
- 1.3 Release and disconnect cable plug -4- .
- 1.4 Unscrew screws -5- and remove change-over valve for high-temperature system -1- .
Change-over valve for high-temperature system (UVW 3)