Installing Adapter Plate For Front Floor
- Apply adhesive evenly on the joint area of the body. > Application depth 0.5 mm
> 5X00IN21 WORKING WITH BODY STRUCTURAL ADHESIVE PAH.071.781.00
Connection areas
- Apply adhesive on adapter plate for front floor.
- 2.1 Apply adhesive evenly over the entire bonding surface. > Application depth 0.5 mm
- 2.2
Also apply a bead of adhesive all around the bonding surface. > Application depth 3 mm
> 5X00IN21 WORKING WITH BODY STRUCTURAL ADHESIVE PAH.071.781.00
Adapter plate for front floor
- Rivet in adapter plate for front floor in areas -A and B-
.
Blind rivets
A Set blind rivets. > BLIND RIVETS 999.190.227.01 B Set blind rivets. > BLIND RIVETS 999.190.230.01 - Screw in and tighten self-tapping screws
> 5X00IN24 SETTING SELF-TAPPING SCREWS
Self-tapping screws