Insulation Test
WARNING: This page is about a different variant/trim than selected.
| Measurement as in 2X00IN | Measuring point | Actual values - Positive to shield | Actual values - Negative to shield | Required |
|---|---|---|---|---|
| Measurement 1 | High-voltage charger → electric passenger compartment heater, air-conditioning compressor | MOhm | MOhm | > 10 MOhm |
| Measurement 2 | High-voltage charger → electric passenger compartment heater | MOhm | MOhm | > 550 MOhm |
| Measurement 2.1 | High-voltage line for electric passenger compartment heater | MOhm | MOhm | > 550 MOhm |
| Measurement 2.2 | Electric passenger compartment heater | MOhm | MOhm | > 550 MOhm |
| Measurement 3 | High-voltage charger → air-conditioning compressor | MOhm | MOhm | > 10 MOhm |
| Measurement 3.1 | High-voltage line for A/C compressor, long (to connection point) | MOhm | MOhm | > 550 MOhm |
| Measurement 3.2 | High-voltage line for A/C compressor, short (from connection point) | MOhm | MOhm | > 550 MOhm |
| Measurement 4 | High-voltage charger → charging socket | MOhm | MOhm | > 550 MOhm |
| Measurement 4.1 | High-voltage charger | MOhm | MOhm | > 550 MOhm |
| Measurement 5 | High-voltage charger → electric motor | MOhm | MOhm | > 550 MOhm |
| Measurement 6 | High-voltage charger → power electronics | MOhm | MOhm | > 550 MOhm |
| Measurement 6.1 | High-voltage line for power electronics | MOhm | MOhm | > 550 MOhm |
| Measurement 6.2 | High-voltage line for high-voltage battery | MOhm | MOhm | > 550 MOhm |
| Measurement 6.3 | E-box | MOhm | MOhm | > 550 MOhm |
| Measurement 7 | Electric motor → power electronics | MOhm | MOhm | > 550 MOhm |
| Measurement 7.1 | Electric motor 3-phase wiring | MOhm | MOhm | > 550 MOhm |
| Measurement 7.2 | 3-phase wiring → (U, V, W) → |
MOhm | MOhm | > 550 MOhm |
| MOhm | MOhm | |||
| MOhm | MOhm | |||
| Measurement 7.3 | Electric motor → (connection U, V, W) → | MOhm | MOhm | > 550 MOhm |
| MOhm | MOhm | |||
| MOhm | MOhm |
Sign the test log and file it in the order folder.
Signature: _______