General information
Model Line:
Macan
Symptom:
No cooling performance from the air-conditioning system.
Cause:
The evaporator for the air-conditioning system can freeze at high outside temperatures and high humidity.
Remedial Action:
Re-program control unit for air-conditioning system using a modified parameter set.
Information
Before doing any other work, the software version must be read out of the air-conditioning control unit using the PIWIS Tester.
→ If the software version is higher than "1040", the remedial action described below must not be carried out .
→ The software in the air-conditioning control unit is already the latest version in this case. Programming the air-conditioning control unit using the programming code will not resolve the problem.
Tools:
Battery Charger/Power Supply - Suitable for AGM Type batteries, recommended current rating of 70A fixed voltage 13.5V to 14.5V.
PIWIS Tester III 9900