Home >> Porsche >> 2017 >> Macan S >> Repair and Diagnosis >> External Pages >> Different car >> Section 776 (87 - Air Conditioning) >> WM 870129 Cleaning refrigerant circuit >> Cleaning refrigerant circuit >> General installation sequence

General installation sequence

WARNING: This page is about a different car, the 2016 Porsche Macan and 2015 Porsche Macan. However, it is still accessible from the selected car via links, so may be relevant.
NOTE: Excessively high pressure in refrigerant circuit
  • Risk of damage to air-conditioning compressor

→ Do not allow low-pressure gauge to go above 3 bar.

Information 

Information 

Information 

Information 

  1. Basic circuit diagrams (flushing circuits) for cleaning with refrigerant R1234yf and R134a 

    With 1 or 2 evaporators

    With and without high-voltage system

    G12890667Courtesy of PORSCHE CARS NORTH AMERICA, INC.
    Air-conditioning servicing equipment (with flushing device)
    High-pressure hose from air-conditioning servicing equipment
    Adapter for connection for the low-pressure side on the refrigerant circuit
    Connection for low-pressure line to air-conditioning compressor
    Adapter for the removed expansion valve
    Evaporator
    Connection for high-pressure line to desiccator
    Adapter for bridging the removed desiccator
    Hose for bridging components
    10  Condenser
    11  Connection for high-pressure line to air-conditioning compressor
    12  Adapter for connection for the high-pressure side on the refrigerant circuit
    13  Hose on flushing device
    14  Flushing device for refrigerant circuits
    15  Low-pressure hose on air-conditioning servicing equipment
    16  Adapter for closing off the outlet to the second evaporator
    17  Adapter for closing off the outlet to the second evaporator
    18  Connection from low-pressure side on refrigerant circuit to the second evaporator
    19  Connection from high-pressure side on refrigerant circuit to the second evaporator
    20  Adapter for the removed expansion valve on the second evaporator
    21  Second evaporator
  2. Install the relevant adapter instead of the expansion valve and tighten it to the same tightening torque as for the expansion valve. → 8X00IN OVERVIEW OF ADAPTERS FOR CLEANING THE REFRIGERANT CIRCUIT

    877019 REMOVING AND INSTALLING EXPANSION VALVE 

    1. 2.1. If you do not have an adapter for the expansion valve: Drill out expansion valve (see "CONVERTING EXPANSION VALVE FOR THE ADAPTER ").
    2. 2.2. Clean the drilled out expansion valve to remove any bits left after machining (chips) and install it. → 877019 REMOVING AND INSTALLING EXPANSION VALVE 
  3. Connect high-pressure hose of the air-conditioning servicing equipment (generally red) to the low-pressure line (line with a larger diameter) for the air-conditioning compressor using the adapter (see overview of adapters → 8X00IN OVERVIEW OF ADAPTERS FOR CLEANING THE REFRIGERANT CIRCUIT) .
    1. 3.1. To do this, the quick connector on the high-pressure line of the air-conditioning servicing equipment must be removed.
  4. Install adapter for bridging the desiccator (see overview of adapters → 8X00IN OVERVIEW OF ADAPTERS FOR CLEANING THE REFRIGERANT CIRCUIT) .
  5. Connect low-pressure hose of the air-conditioning servicing equipment (generally blue) to the outlet of the flushing device (chip filter) -14-  for refrigerant circuits using the quick connector.
  6. Connect hose on flushing device -13-  of the air-conditioning servicing equipment to the high-pressure line (line with the smaller diameter) for the air-conditioning compressor using the adapter (see overview of adapters → 8X00IN OVERVIEW OF ADAPTERS FOR CLEANING THE REFRIGERANT CIRCUIT) .

    Information 

    • Only when clear, totally colorless refrigerant flows through the inspection glass of the flushing device for refrigerant circuits into the air-conditioning servicing equipment is the refrigerant circuit cleaned.
    • Flushing washes all refrigerant oil out of the refrigerant circuit (except for minute traces - but these can be ignored).
    • If the refrigerant circuit is extremely dirty, it may be necessary to perform the flushing cycle twice (two flushing cycles with three flushing procedures each). Before starting the second flushing cycle, the filter on the flushing device must be replaced by a new filter (see Workshop Equipment and Special Tools Manual).
  7. Flush the refrigerant circuit as described in the operating instructions for the air-conditioning servicing equipment.

    Information 

    • If a flushed refrigerant circuit will not be assembled again immediately after flushing, leave the adapters on the connections and close off the connections on the adapters using sealing caps VAS 6338/30.
  8. After flushing, check the pressure in the refrigerant circuit. There must be no overpressure in the refrigerant circuit (evacuate the refrigerant circuit again briefly if necessary).
  9. Close off connections to the air-conditioning servicing equipment from the refrigerant circuit in the vehicle. There must be no overpressure in the refrigerant circuit.
  10. The following components must be replaced if the air-conditioning compressor is seized up: Air-conditioning compressor, expansion valve, desiccator or condenser with desiccator.

    If the refrigerant circuit is cleaned without causing damage, only the desiccator or the condenser with desiccator must be replaced.

  11. Determine refrigerant oil quantity for the refrigerant circuit.
    1. 11.1. A new air-conditioning compressor is pre-filled with a certain amount of refrigerant oil and this must be taken into account when determining the total amount of refrigerant oil.
    2. 11.2. If the same air-conditioning compressor is installed again, the amount of refrigerant oil in the air-conditioning compressor must be measured in order to determine the total amount of refrigerant oil.