LEMON Manuals: Even more car manuals for everyone
Home >> Porsche >> 2016 >> 911 Turbo, 2D Convertible >> Repair and Diagnosis >> External Pages >> Different car >> Section 130 (97 - Cables -- CARRERA (997)) >> WM 9772IN Optical WAVEGUIDE (LWL) - Most Bus (All Models) >> Optical Waveguide (LWL) - MOST Bus >> Requirements When Working With LWL

Requirements When Working With LWL

WARNING: This page does not describe the selected car, but rather 9 other vehicles, including the 2013 Porsche 911, 2012 Porsche 911, 2011 Porsche 911, 2010 Porsche 911, and 2009 Porsche 911. However, it is still accessible from the selected car via links, so may be relevant.

The plug connections must not be plugged or separated with tools.

The LWL and the plug connections must not come into contact with fluids such as water, creeping compound, preservative, anti-freeze protection, cleaning agent. They will impair the MOST system function or cause complete system failure. Even plug connectors with plugged-in protective caps must not come into contact with the fluids listed.

If the optical contacts, plug connections, or sockets are not plugged in, or if there are no protective caps installed on the plug, contact with dust and other solid materials (lubricants) must also be avoided.

The optical contacts, plug connectors, or sockets must not be cleaned.