DIAGNOSIS/TROUBLESHOOTING (8009 CDR23)

Work instruction Display OK If not OK
1 MOST component check runs automatically
  • Connect the Porsche System Tester II 9588 to the diagnostic socket, start it and switch on the ignition
  • Select 911 (996) in the Vehicle type menu and confirm with the "FORWORD" key.
  • Select CDR23 in the Control units menu and confirm with the "FORWORD" key.
  • Select MOST components check in the PCM2 function selection and confirm with the "FORWORD" key.
  • Follow the instructions of the tester
The following text is displayed:
Test successfully completed. No faults found
-> End
Tester displays an optical fault:
Under Faulty device, the tester displays the relevant MOST control module from which a corresponding signal is not recognized
Step 2
Tester displays an electrical fault
Step 7
2 Open circuit in MOST, optical
  • Replace the optical waveguide for the MOST control module with the optical waveguide test line 9712
  • Clear fault memory 8009
  • Select MOST components check and start it again with the "FORWORD" key
  • Follow the instructions of the tester
The following text is displayed:
Test successfully completed. No faults found
Step 3
Step 4
3 Replace the optical waveguide -> End
4 Open circuit in MOST, optical If an MMI or GW fault is displayed under step 1.
  • Connect optical output with the optical input of the MOST control module which is installed before the CDR23 with the optical waveguide test line 9712

If only 1 external MOST control module is present and fault memory entry under step 1 is not MMI or GW:
Otherwise
  • Connect the optical waveguide test line 9712 with the following Most control module displayed under step 1 (do not change the input of the optical waveguide test line).

After installation Optical waveguide test line 9712:
  • Clear fault memory 8009
  • Select MOST components check and start it again with the "FORWORD" key.
  • Follow the instructions of the tester
If an MMI or GW fault is displayed under step 1:
fault memory entry 8009 = MMI or GW
Step 5
If only 1 external MOST control module is present and fault memory entry under step 1 is not MMI or GW:
fault memory entry 8009 = MMI or GW
Step 6
Otherwise:
The following text is displayed:
Test successfully completed. No faults found.
Step 6
-> End
If an MMI or GW fault is displayed under step 1:
fault memory entry 8009 is not MMI or GW
Step 6
If only 1 external MOST control module is present and fault memory entry under step 1 is not MMI or GW:
fault memory entry 8009 is not MMI or GW
Step 5
Otherwise:
Step 7
5 Replace the control module displayed under step 1. -> End
6 Replace the control module before the one displayed under step 1. -> End
7 Check the power supply of the displayed control module Step 6 Repair
-> End
8 Check wiring of the ring break diagnosis line Step 6 Repair
-> End
9 Replace displayed control module -> End