Fault code 14: Diagnosis/troubleshooting
DIAGNOSIS/TROUBLESHOOTING FOR FAULT CODE 14
| Work instruction | Display OK | If not OK | ||
|---|---|---|---|---|
| 1 | Check battery |
|
Step 2 | Charge or replace battery -> End |
| 2 | Check the generator |
|
Approx. 14 V Step 3 |
Step 4 |
| 3 | Check input voltage of the control module |
|
Approx. 12 V ->End |
Check plug connections for corrosion and contact resistance -> End |
| 4 |
|
-> End | ||