Installation Procedure

    Fig 1: Installing Input Shaft Seal
    GM848536Courtesy of GENERAL MOTORS CORP.
    IMPORTANT: Take care to prevent cutting of the input shaft seal on the input shaft splines.
  1. Install the input shaft seal. Refer to Torque Converter Fluid Seal Replacement .
  2. Fig 2: Torque Converter
    GM1955709Courtesy of GENERAL MOTORS CORP.
    IMPORTANT: Ensure the torque converter is fully seated into the transmission pump drive gear and turbine shaft.
  3. Install the torque converter. Push the torque converter into position while rotating.
    • The torque converter must be fully seated on the turbine shaft
    • The torque converter must be fully seated in the pump drive gear
  4. Install the transmission to the vehicle. Refer to Transmission Replacement .
  5. IMPORTANT: It is recommended that transmission adaptive pressure (TAP) information be reset.
    Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM or TCM will need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.