Installation Procedure
- Install new O-ring seals (3-4) to the pressure control solenoid (1), if the O-rings were previously removed.
- Install the pressure control solenoid (1) into the control valve body.
- Install the pressure control solenoid retainer into the control valve body.
- Connect the electrical connector (2) to the pressure control solenoid (1).
- Install the transmission fluid pan and filter. Refer to Automatic Transmission Fluid and Filter Replacement .
- Reset the TAP values. Refer to Transmission Adaptive Functions .
IMPORTANT:
It is recommended that transmission adaptive pressure (TAP) information be reset.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM or TCM will need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.
Resetting the TAP values using a scan tool will erase all learned values in all cells. As a result, The ECM or TCM will need to relearn TAP values. Transmission performance may be affected as new TAP values are learned.