Control Valve Body Accumulator Assembly Assemble

    Fig 1: View Of Pressure Control Solenoid
    GM801956Courtesy of GENERAL MOTORS CORP.
  1. Install the pressure control solenoid (357).
  2. Install the pressure control solenoid retainer (351).
  3. Fig 2: Identifying Feed Limit Valve
    GM801954Courtesy of GENERAL MOTORS CORP.
  4. Install the feed limit valve (353).
  5. Install the feed limit valve spring (354).
  6. Install the feed limit valve retainer (343).
  7. Fig 3: Expanded View Of TCC PWM Solenoid & TCC Regulator Apply Valve
    GM801953Courtesy of GENERAL MOTORS CORP.
  8. Install the tcc pwm solenoid valve spring (347).
  9. Install the tcc regulator apply valve (348).
  10. Install the tcc pwm solenoid (352).
  11. Install the tcc pwm solenoid retainer (351).
  12. Fig 4: Locating 3-4 Shift Valve
    GM801952Courtesy of GENERAL MOTORS CORP.
  13. Install the 3-4 shift control valve (346).
  14. Install the 3-4 shift valve (345).
  15. Install the 3-4 shift valve spring (344).
  16. Install the 3-4 shift control valve retainer (343).
  17. Fig 5: View Of Safety Mode Valve Components
    GM801951Courtesy of GENERAL MOTORS CORP.
  18. Install the safety mode valve (341).
  19. Install the safety mode valve spring (342).
  20. Install the safety mode valve retainer (343).