LEMON Manuals: Even more car manuals for everyone
Home >> Pontiac >> 2007 >> Solstice GXP, Standard >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 1 (Automatic Transmission - 5L40-E/5L50-E - Introduction (2 Of 2)) >> Repair Instructions >> Repair Instructions - Off Vehicle >> Torque Converter Housing Installation

Torque Converter Housing Installation

WARNING: This page is about a different variant/trim than selected.

Tools Required 

J 36850  Transjel Lubricant

    Fig 1: Measuring Dimension X
    GM816741Courtesy of GENERAL MOTORS CORP.
  1. Measure the distance from the bottom of the gage bar to the top of the direct and reverse clutch assembly (6). Record this as dimension X. Refer to the Reverse Clutch Housing Selective Thrust Washer Specifications  to determine the correct size to use.
  2. Fig 2: Locating Torque Converter Fluid Seal
    GM801919Courtesy of GENERAL MOTORS CORP.
  3. Use J 36850  to install the NEW torque converter fluid seal (4) onto the torque converter housing.
  4. Use J 36850  to install the reverse clutch housing thrust washer (5).
  5. Fig 3: Installing Fluid Pump Cover Gasket
    GM801920Courtesy of GENERAL MOTORS CORP.
  6. Install the NEW fluid pump cover gasket (46).
  7. Install the torque converter housing (3) onto the case (24).
  8. Install the torque converter housing bolts (2) and hand tighten.
  9. Fig 4: Identifying Torque Converter Housing Bolts Tightening Sequence
    GM801921Courtesy of GENERAL MOTORS CORP.
    NOTE: Refer to Fastener Notice .
  10. Tighten the torque converter housing bolts in sequence.

    Tighten:  Tighten the housing bolts to 22 N.m (16 lb ft).