- Apply J 36850 to the new fluid pump seal.
- Install the fluid pump assembly (2) onto transaxle case. Secure with the six bolts.
Tighten: Tighten fluid pump bolts to 25 N.m (18 lb ft).
- Measure the input shaft end play using a J 7872
. See Special Tools .
- Place the J 7872 on the end of the input shaft and gently move the input shaft up and down using 2 screwdrivers. See Special Tools . Observe the J 7872 . See Special Tools .
- Verify that the input shaft end play falls within 0.3-0.9 mm (0.012-0.035 in).
- If the input shaft does not fall within specification, replace the forward clutch outer bearing race on the end of the fluid pump stator shaft with a suitable size race.
- The following are the 2 available forward clutch outer race sizes: 0.8 mm (0.031 in) and 1.4 mm (0.055 in).
- Install the differential lubrication seal (1) into the transaxle case (2).
- Install the differential assembly (2) into the transaxle case (1).
- Apply RTV silicone sealer GM P/N 1052917, or equivalent, to the torque converter housing mating surface.
- Install the torque converter housing (3) onto the transaxle case. Secure the housing assembly with the seventeen bolts (2).
Tighten: Tighten the torque converter housing bolts to 29 N.m (21 lb ft).