LEMON Manuals: Even more car manuals for everyone
Home >> Plymouth >> 1999 >> Breeze 2.4 X >> Repair and Diagnosis >> Restraints >> Air Bag, SRS >> Air Bag Restraint Systems - Except Coupe >> Diagnostic Tests >> Test 6A - Driver Squib Term Shorted To Ground

Test 6A - Driver Squib Term Shorted To Ground

NOTE: Perform TEST VER-1A - VERIFICATION TEST  after all repairs. Each time a connector is disconnected, inspect it to ensure it is in good condition. Always focus on circuit being tested. Dirt, water and corrosion, are most common problems in connectors. Due to manufacturer changes in wire colors, use terminal identification whenever possible.
  1. Disconnect battery and wait 2 minutes before proceeding. Disconnect driver-side air bag module. Turn ignition on and then reconnect battery. Using DRB, read active codes. If DRB displays DRIVER SQUIB TERM SHORTED TO GROUND, go to next step. If not, replace driver-side air bag module.
  2. Disconnect clockspring 2-pin connector. Using DRB, read active codes. If DRB displays DRIVER SQUIB TERM SHORTED TO GROUND, go to next step. If not, replace clockspring.
  3. Disconnect battery and wait 2 minutes before proceeding. Disconnect air bag control module 4-pin connector. Turn ignition on, then reconnect battery. Using DRB, read active codes. If DRB displays DRIVER SQUIB TERM SHORTED TO GROUND, replace ACM. If not, repair short between driver-side air bag module and ACM 4-pin connector (Black/Light Blue wire and Dark Green/Light Blue wire). See WIRING DIAGRAMS  .