LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different variant/trim >> Section 13 (Engine Control System (DTC/Circuit Diagnosis) (5.6L) (3 Of 6)) >> DTC/Circuit Diagnosis >> DTC P0182: FTT Sensor >> DTC Diagnosis Procedure

DTC Diagnosis Procedure

WARNING: This page is about a different variant/trim than selected.
  1. CHECK FUEL TANK TEMPERATURE SENSOR POWER SUPPLY CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect "fuel level sensor unit and fuel pump" harness connector.
    3. Turn ignition switch ON.
    4. Check the voltage between "fuel level sensor unit and fuel pump" harness connector and ground.

      Fuel level sensor unit and fuel pump

      Ground

      Voltage (V)

      Connector

      Terminal

      C37

      4

      Ground

      Approx. 5

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    GO TO 2.

  2. DETECT MALFUNCTIONING PART 

    Check the following.

    • Harness for open or short between ECM and "fuel level sensor unit and fuel pump"
    • Loose or poor connection for each connector and harness

    Repair open circuit, short to ground or short to power in harness or connector.

  3. CHECK FUEL TANK TEMPERATURE SENSOR POWER SUPPLY CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between fuel tank temperature sensor harness connector and ECM harness connector.

    Fuel level sensor unit and fuel pump

    ECM

    Continuity

    Connector

    Terminal

    Connector

    Terminal

    C37

    4

    E77

    128

    Existed

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    Repair or replace error-detected parts.

  4. CHECK FUEL TANK TEMPERATURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between fuel level sensor unit and fuel pump harness connector and ECM harness connector.

      Fuel level sensor unit and fuel pump

      ECM

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      C37

      6

      E77

      148

      Existed

    4. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES

    GO TO 6.

    NO

    GO TO 5.

  5. DETECT MALFUNCTIONING PART 

    Check the following.

    • Harness for open or short between "fuel level sensor unit and fuel pump" and "combination meter"
    • Loose or poor connection for each connector and harness

    Repair open circuit, short to ground or short to power in harness or connector.

  6. CHECK FUEL TANK TEMPERATURE SENSOR 

    Refer to Component Inspection (Fuel Tank Temperature Sensor) .

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    Replace "fuel level sensor unit and fuel pump". Refer to Removal and Installation - VK56VD .