DTC Diagnosis Procedure
- CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect EVAP canister purge volume control solenoid valve harness connector.
- Turn ignition switch ON.
- Check the voltage between EVAP canister purge volume control solenoid valve harness connector and ground.
EVAP canister purge volume control solenoid valve
Ground
Voltage
Connector
Terminal
F30
1
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 3.
NO
GO TO 2.
- DETECT MALFUNCTIONING PART
Check the following.
- Harness for open or short between EVAP canister purge volume control solenoid valve and IPDM E/R
- Harness for open or short between EVAP canister purge volume control solenoid valve and ECM
- Loose or poor connection for each connector and harness
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between EVAP canister purge volume control solenoid valve harness connector and ECM harness connector.
EVAP canister purge volume control solenoid valve
ECM
Continuity
Connector
Terminal
Connector
Terminal
F30
2
F78
106
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 4.
NO
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR CONNECTOR
- Disconnect EVAP control system pressure sensor harness connector.
- Check that water is not inside connectors.
Is the inspection result normal?
YES
GO TO 5.
NO
Replace EVAP control system pressure sensor.
- CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
Refer to Component Inspection (EVAP Control System Pressure Sensor) .
Is the inspection result normal?
YES
With CONSULT: GO TO 6.
YES
Without CONSULT: GO TO 7.
NO
Replace EVAP control system pressure sensor.
- CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
WITH CONSULT
- Turn ignition switch OFF.
- Reconnect harness connectors disconnected.
- Start engine.
- Perform "PURG VOL CONT/V" in "ACTIVE TEST" mode with CONSULT. Check that engine speed varies according to the valve opening.
Does engine speed vary according to the valve opening?
YES
GO TO 8.
NO
GO TO 7.
- CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE
Refer to Component Inspection (EVAP Canister Purge Volume Control Solenoid Valve) .
Is the inspection result normal?
YES
GO TO 8.
NO
Replace EVAP canister purge volume control solenoid valve. Refer to Exploded View .
- CHECK RUBBER TUBE FOR CLOGGING
- Disconnect rubber tube connected to EVAP canister vent control valve.
- Check the rubber tube for clogging.
Is the inspection result normal?
YES
GO TO 9.
NO
Clean the rubber tube using an air blower.
- CHECK EVAP CANISTER VENT CONTROL VALVE
Refer to Component Inspection (EVAP Canister Vent Control Valve) .
Is the inspection result normal?
YES
GO TO 10.
NO
Replace EVAP canister vent control valve. Refer to Removal and Installation .
- CHECK IF EVAP CANISTER IS SATURATED WITH WATER
- Remove EVAP canister with EVAP canister vent control valve and EVAP control system pressure sensor attached.
- Check if water will drain from EVAP canister (1).
- EVAP canister vent control valve (2)
Does water drain from the EVAP canister?
YES
GO TO 11.
NO
INSPECTION END
- CHECK EVAP CANISTER
Weigh the EVAP canister with the EVAP canister vent control valve and EVAP control system pressure sensor attached.
The weight should be less than 2.5 kg (5.5 lb).
Is the inspection result normal?
YES
INSPECTION END
NO
GO TO 12.
- DETECT MALFUNCTIONING PART
Check the following.
- EVAP canister for damage
- EVAP hose between EVAP canister and vehicle frame for clogging or poor connection
Repair hose or replace EVAP canister. Refer to Removal and Installation .