Diagnosis Procedure
- INSPECTION START
Confirm the detected malfunction (A or B). Refer to DTC Description .
Which malfunction is detected?
A
GO TO 2.
B
GO TO 5.
- CHECK FUEL TANK TEMPERATURE SENSOR POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect fuel level sensor unit and fuel pump harness connector.
- Turn ignition switch ON.
- Check the voltage between fuel level sensor unit and fuel pump harness connector and ground.
+
-
Voltage
Fuel level sensor unit and fuel pump
Connector
Terminal
B42
3
Ground
Approx. 5 V
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 3.
- CHECK FUEL TANK TEMPERATURE SENSOR POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between fuel tank temperature sensor harness connector and ECM harness connector.
Fuel level sensor unit and fuel pump
ECM
Continuity
Connector
Terminal
Connector
Terminal
B42
3
E10
128
Existed
Is the inspection result normal?
YES
Perform the trouble diagnosis for power supply circuit.
NO
Repair or replace error-detected parts.
- CHECK FUEL TANK TEMPERATURE SENSOR GROUND CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between fuel level sensor unit and fuel pump harness connector and ECM harness connector.
Fuel level sensor unit and fuel pump
ECM
Continuity
Connector
Terminal
Connector
Terminal
B42
1
E10
148
Existed
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 5.
NO
Repair open circuit, short to ground or short to power in harness or connector.
- CHECK FUEL TANK TEMPERATURE SENSOR
Check fuel tank temperature sensor. Refer to Component Inspection .
Is the inspection result normal?
YES
INSPECTION END
NO
Replace fuel level sensor unit and fuel pump. Refer to Removal and Installation .