Component Inspection
- INSPECTION START
Will CONSULT be used?
Will CONSULT be used?
YES
GO TO 2.
NO
GO TO 3.
- CHECK HEATED OXYGEN SENSOR 2
With CONSULT
- Turn ignition switch ON and select "DATA MONITOR" mode with CONSULT.
- Start engine and warm it up to the normal operating temperature.
- Turn ignition switch OFF and wait at least 10 seconds.
- Start engine and keep the engine speed between 3, 500 and 4, 000 rpm for at least 1 minute under no load.
- Let engine idle for 1 minute.
- Select "FUEL INJECTION" in "ACTIVE TEST" mode, and select "HO2S2 (B1)/(B2)" as the monitor item with CONSULT.
- Check "HO2S2 (B1)/(B2)" at idle speed when adjusting "FUEL INJECTION" to ± 25%.
: The voltage should be above 0.72 V at least on time.
: The voltage should be below 0.27 V at least on time.
"HO2S2 (B1)/(B2)" should be above 0.68 V at least once when the "FUEL INJECTION" is + 25%.
"HO2S2 (B1)/(B2)" should be below 0.18 V at least once when the "FUEL INJECTION" is - 25%.
Is the inspection result normal?
YES
INSPECTION END
NO
Replace malfunctioning heated oxygen sensor 2. Refer to Removal and Installation (bank 2) , Removal and Installation (bank 1) .
- CHECK HEATED OXYGEN SENSOR 2-I
Without CONSULT
- Start engine and warm it up to the normal operating temperature.
- Turn ignition switch OFF and wait at least 10 seconds.
- Start engine and keep the engine speed between 3, 500 and 4, 000 rpm for at least 1 minute under no load.
- Let engine idle for 1 minute.
- Check the voltage between ECM harness connector terminals under the following conditions.
ECM
Condition
Voltage
Connector
+
-
Terminal
F13
32
35
Revving up to 4, 000 rpm under no load at least 10 times
The voltage should be above 0.72 V at least once during this procedure.
The voltage should be below 0.27 V at least once during this procedure.
41
Is the inspection result normal?
YES
INSPECTION END
NO
GO TO 4.
- CHECK HEATED OXYGEN SENSOR 2-II
Check the voltage between ECM harness connector terminals under the following conditions.
ECM
Condition
Voltage
Connector
+
-
Terminal
F13
32
35
Keeping engine at idle for 10 minutes
The voltage should be above 0.72 V at least once during this procedure.
The voltage should be below 0.27 V at least once during this procedure.
41
Is the inspection result normal?
YES
INSPECTION END
NO
GO TO 5.
- CHECK HEATED OXYGEN SENSOR 2-III
Check the voltage between ECM harness connector terminals under the following conditions.
ECM
Condition
Voltage
Connector
+
-
Terminal
F13
32
35
Coasting from 80 km/h (50 MPH) with selector lever in the D position
The voltage should be above 0.72 V at least once during this procedure.
The voltage should be below 0.27 V at least once during this procedure.
41
Is the inspection result normal?
YES
INSPECTION END
NO
Replace malfunctioning heated oxygen sensor 2. Refer to Removal and Installation (bank 2) , Removal and Installation (bank 1) .