Diagnosis Procedure
- RETIGHTEN A/F SENSOR 1 AND HEATED OXYGEN SENSOR 2
Loosen and retighten the A/F sensor 1 and heated oxygen sensor 2. Refer to Removal and Installation (bank 2) , Removal and Installation (bank 1) .
GO TO 2.
- CHECK FOR EXHAUST GAS LEAK
- Start engine and run it at idle.
- Listen for an exhaust gas leak before the three way catalyst 2.
Is exhaust gas leak detected?
YES
Repair or replace.
NO
GO TO 3.
- CHECK FOR INTAKE AIR LEAKAGE
- Start engine and run it at idle.
- Listen for an intake air leakage after the mass air flow sensor.
Is intake air leakage detected?
YES
Repair or replace malfunctioning part.
NO
GO TO 4.
- CLEAR THE MIXTURE RATIO SELF-LEARNING VALUE
- Clear the mixture ratio self-learning value. Refer to Description .
- Run engine for at least 10 minutes at idle speed.
Is the 1st trip DTC P0171, P0172, P0174 or P0175 detected? Is it difficult to start engine?
YES
Perform trouble diagnosis for DTC P0171, P0174 or P0172, P0175. Refer to DTC Description or DTC Description .
NO
GO TO 5.
- CHECK HARNESS CONNECTOR
- Turn ignition switch OFF.
- Disconnect A/F sensor 1 harness connector.
- Check harness connector for water.
Water should not exit.
Is the inspection result normal?
YES
GO TO 6.
NO
Repair or replace harness connector.
- CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY
- Disconnect A/F sensor 1 harness connector.
- Turn ignition switch ON.
- Check the voltage between A/F sensor 1 harness connector and ground.
DTC
+
-
Voltage
A/F sensor
Bank
Connector
Terminal
P2096
P2097
1
F12
1
Ground
Battery voltage
P2098
P2099
2
F61
1
Is the inspection result normal?
YES
GO TO 8.
NO
GO TO 7.
- CHECK AIR FUEL RATIO (A/F) SENSOR 1 POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between A/F sensor 1 harness connector and IPDM E/R harness connector.
DTC
A/F sensor 1
IPDM E/R
Continuity
Bank
Connector
Terminal
Connector
Terminal
P2096
P2097
1
F12
1
F50
52
Existed
P2098
P2099
2
F61
1
53
Is the inspection result normal?
YES
Perform the trouble diagnosis for power supply circuit.
NO
Repair or replace error-detected parts.
- CHECK A/F SENSOR 1 INPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between A/F sensor 1 harness connector and ECM harness connector.
DTC
A/F sensor 1
ECM
Continuity
Bank
Connector
Terminal
Connector
Terminal
P2096
P2097
1
F12
3
F14
66
Existed
4
67
P2098
P2099
2
F61
3
76
4
77
- Check the continuity between A/F sensor 1 harness connector and ground, or ECM harness connector and ground.
DTC
A/F sensor 1
Ground
Continuity
Bank
Connector
Terminal
P2096
P2097
1
F12
3
Ground
Not existed
4
P2098
P2099
2
F61
3
4
DTC
ECM
Ground
Continuity
Connector
Terminal
P2096
P2097
F14
66
Ground
Not existed
67
P2098
P2099
76
77
- Also check harness for short to power.
Is the inspection result normal?
YES
GO TO 9.
NO
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK A/F SENSOR 1 HEATER
Check A/F sensor 1 heater. Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 10.
NO
GO TO 11.
- CHECK HEATED OXYGEN SENSOR 2
Check heated oxygen sensor 2. Refer to Component Inspection .
Is the inspection result normal?
YES
INSPECTION END
NO
Replace malfunctioning heated oxygen sensor 2.
- REPLACE AIR FUEL RATIO (A/F) SENSOR 1
Replace malfunctioning air fuel ratio (A/F) sensor 1. Refer to Removal and Installation (bank 2) , Removal and Installation (bank 1) .
Do you have CONSULT?
YES
GO TO 12.
NO
GO TO 13.
- CONFIRM A/F ADJUSTMENT DATA
With CONSULT
- Turn ignition switch ON.
- Select "A/F ADJ-B1" and "A/F ADJ-B2" in "DATA MONITOR" mode with CONSULT.
- Make sure that "0.000" is displayed on CONSULT screen.
Is "0.000" displayed?
YES
INSPECTION END
NO
GO TO 13.
- CLEAR THE MIXTURE RATIO SELF-LEARNING VALUE
Clear the mixture ratio self-learning value. Refer to Description .
Do you have CONSULT?
YES
GO TO 14.
NO
INSPECTION END
- CONFIRM A/F ADJUSTMENT DATA
With CONSULT
- Turn ignition switch ON.
- Select "A/F ADJ-B1" and "A/F ADJ-B2" in "DATA MONITOR" mode with CONSULT.
- Make sure that "0.000" is displayed on CONSULT screen.
INSPECTION END