Diagnosis Procedure
- CHECK HO2S2 POWER SUPPLY
- Disconnect heated oxygen sensor 2 (HO2S2) harness connector.
- Turn ignition switch ON.
- Check the voltage between HO2S2 harness connector and ground.
DTC
+
-
Voltage
HO2S2
Bank
Connector
Terminal
P00D2
1
F62
1
Ground
Battery voltage
P00D4
2
F56
1
Is the inspection result normal?
YES
GO TO 3.
NO
GO TO 2.
- CHECK HO2S2 SENSOR 1 POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between HO2S2 harness connector and IPDM E/R harness connector.
DTC
HO2S2
IPDM E/R
Continuity
Bank
Connector
Terminal
Connector
Terminal
P00D2
1
F62
1
F50
52
Existed
P00D4
2
F56
1
53
Is the inspection result normal?
YES
Perform the trouble diagnosis for power supply circuit.
NO
Repair or replace error-detected parts.
- CHECK HO2S2 HEATER OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT
- Turn ignition switch OFF.
- Disconnect ECM harness connector.
- Check the continuity between HO2S2 harness connector and ECM harness connector.
DTC
HO2S2
ECM
Continuity
Bank
Connector
Terminal
Connector
Terminal
P00D2
1
F62
2
F13
7
Existed
P00D4
2
F56
2
47
- Also check harness for short to ground and short to power.
Is the inspection result normal?
YES
GO TO 4.
NO
Repair open circuit, short to ground or short to power in harness or connectors.
- CHECK HEATED OXYGEN SENSOR 2 HEATER
Check heated oxygen sensor 2 heater. Refer to Component Inspection .
Is the inspection result normal?
YES
INSPECTION END
NO
Replace malfunctioning heated oxygen sensor 2. Refer to Removal and Installation (bank 2) , Removal and Installation (bank 1) .