  1. CHECK HO2S2 POWER SUPPLY 
    1. Disconnect heated oxygen sensor 2 (HO2S2) harness connector.
    2. Turn ignition switch ON.
    3. Check the voltage between HO2S2 harness connector and ground.

      DTC

      +

      -

      Voltage

      HO2S2

      Bank

      Connector

      Terminal

      P00D2

      1

      F62

      1

      Ground

      Battery voltage

      P00D4

      2

      F56

      1

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    GO TO 2.

  2. CHECK HO2S2 SENSOR 1 POWER SUPPLY CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect IPDM E/R harness connector.
    3. Check the continuity between HO2S2 harness connector and IPDM E/R harness connector.

    DTC

    HO2S2

    IPDM E/R

    Continuity

    Bank

    Connector

    Terminal

    Connector

    Terminal

    P00D2

    1

    F62

    1

    F50

    52

    Existed

    P00D4

    2

    F56

    1

    53

    Is the inspection result normal?

    YES

    Perform the trouble diagnosis for power supply circuit.

    NO

    Repair or replace error-detected parts.

  3. CHECK HO2S2 HEATER OUTPUT SIGNAL CIRCUIT FOR OPEN AND SHORT 
    1. Turn ignition switch OFF.
    2. Disconnect ECM harness connector.
    3. Check the continuity between HO2S2 harness connector and ECM harness connector.

      DTC

      HO2S2

      ECM

      Continuity

      Bank

      Connector

      Terminal

      Connector

      Terminal

      P00D2

      1

      F62

      2

      F13

      7

      Existed

      P00D4

      2

      F56

      2

      47

    4. Also check harness for short to ground and short to power.

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    Repair open circuit, short to ground or short to power in harness or connectors.

  4. CHECK HEATED OXYGEN SENSOR 2 HEATER 

    Check heated oxygen sensor 2 heater. Refer to Component Inspection .

    Is the inspection result normal?

    YES

    INSPECTION END

    NO

    Replace malfunctioning heated oxygen sensor 2. Refer to Removal and Installation (bank 2) , Removal and Installation (bank 1) .