Diagnosis Procedure (Cooling Fan Motor)
- CHECK COOLING FAN CONTROL MODULE POWER SUPPLY-I
- Turn ignition switch OFF.
- Disconnect cooling fan control module harness connector.
- Turn ignition switch ON.
- Check the voltage between cooling fan control module harness connector and ground.
+
-
Voltage
Cooling fan control module
Connector
Terminal
E225
3
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 11.
NO
GO TO 2.
- CHECK COOLING FAN CONTROL MODULE POWER SUPPLY-II
- Turn ignition switch OFF.
- Remove cooling fan relay.
- Check the voltage between cooling fan relay harness connector and ground.
+
-
Voltage
Cooling fan relay
Connector
Terminal
E82
3
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 3.
- CHECK FUSIBLE LINK
Check that 60A fusible link (No. H) is not blowing.
Is the fusible link blown (open)?
YES
Perform trouble diagnosis for power supply circuit.
NO
Replace the fusible link after repairing the applicable circuit.
- CHECK COOLING FAN CONTROL MODULE POWAR SUPPLY CIRCUIT
- Check the continuity between cooling fan relay harness connector and cooing fan control module harness connector.
Cooling fan relay
Cooling fan control module
Continuity
Connector
Terminal
Connector
Terminal
E82
5
E225
3
Existed
- Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
GO TO 5.
NO
Repair or replace error-detected parts.
- Check the continuity between cooling fan relay harness connector and cooing fan control module harness connector.
- CHECK COOLING FAN RELAY DRIVE POWER SUPPLY
- Turn ignition switch ON.
- Check the voltage between cooling fan relay harness connector and ground.
+
-
Voltage
Cooling fan relay
Connector
Terminal
E82
1
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 8.
NO
GO TO 6.
- CHECK FUSE
- Turn ignition switch OFF.
- Check that 10A fuse (No. 48) is not blowing.
Is the fuse blown (open)?
YES
GO TO 7.
NO
Replace the fuse after repairing the applicable circuit.
- CHECK COOLING FAN RELAY DRIVE POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and cooing fan relay harness connector.
IPDM E/R
Cooling fan relay
Continuity
Connector
Terminal
Connector
Terminal
E119
36
E82
1
Existed
- Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
GO TO 10
NO
Repair or replace error-detected parts.
- CHECK COOLING FAN RELAY DRIVE SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector.
- Check the continuity between IPDM E/R harness connector and cooing fan relay harness connector.
IPDM E/R
Cooling fan relay
Continuity
Connector
Terminal
Connector
Terminal
E119
27
E82
2
Existed
- Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
GO TO 9.
NO
Repair or replace error-detected parts.
- CHECK COOLING FAN RELAY
Refer to Component Inspection (Cooling Fan Relay) .
Is the inspection result normal?
YES
GO TO 10.
NO
Replace cooling fan relay.
- CHECK INTERMITTENT INCIDENTE
Perform Intermittent Incident .
Is the inspection result normal?
YES
Replace IPDM E/R. Refer to Removal and Installation .
NO
Repair or replace error-detected parts.
- CHECK COOLING FAN CONTROL MODULE GROUND CIRCUIT
- Turn ignition switch OFF.
- Check the continuity between cooling fan control module harness circuit.
Cooling fan control module
--
Continuity
Connector
Terminal
E225
1
Ground
Existed
- Also check harness for short to power.
Is the inspection result normal?
YES
GO TO 12.
NO
Repair or replace error-detected parts.
- CHECK COOLING FAN CONTROL SIGNAL
- Reconnect cooling fan control module harness connector.
- Start engine.
- Check the voltage between IPDM E/R harness connector and ground.
+
-
Condition
Voltage
IPDM E/R
Connector
Terminal
E218
93
Ground
Engine idling
0 - 5 V
Is the inspection result normal?
YES
GO TO 13.
NO
GO TO 10.
- CHECK COOLING FAN CONTROL SIGNAL CIRCUIT
- Turn ignition switch OFF.
- Disconnect IPDM E/R harness connector and cooling fan control module harness connector.
- Check the continuity between IPDM E/R harness connector and cooing fan control module harness connector.
IPDM E/R
Cooling fan control module
Continuity
Connector
Terminal
Connector
Terminal
E218
93
E225
2
Existed
- Also check harness for short to power and short to ground.
Is the inspection result normal?
YES
GO TO 14.
NO
Repair or replace error-detected parts.
- CHECK COOLING FAN CONTROL MODULE OUTPUT SIGNAL
- Reconnect all harness connectors disconnected.
- Disconnect cooling fan control module harness connector.
- Turn ignition switch ON.
- Check the voltage between cooling fan control module connector and ground.
+
-
Voltage
Cooling fan control module
Motor
Connector
Terminal
1
E245
4
Ground
Battery voltage
2
E246
6
Is the inspection result normal?
YES
GO TO 15.
NO
Replace cooling fan control module. Refer to Exploded View .
- CHECK COOLING FAN MOTOR
Refer to Component Inspection (Cooling Fan Motor) .
Is the inspection result normal?
YES
Perform intermittent incident. Refer to Intermittent Incident
NO
Replace malfunctioning cooling fan motor. Refer to Exploded View .