Diagnosis Procedure
- CALIBRATION OF AUTOMATIC BACK DOOR POSITION INFORMATION
- Perform initialization setting of automatic back door position information.
Refer to Work Procedure .
- Erase DTC, and then repeat "PERFORM DTC CONFIRMATION PROCEDURE".
Is DTC detected?
YES
GO TO 2.
NO
Inspection End.
- Perform initialization setting of automatic back door position information.
- CHECK INSTALLATION OF BACK DOOR ASSEMBLY
- Check that back door assembly is installed normally.
Refer to Adjustment .
- Check back door assembly mechanism deformation, looseness, rattle, interference with other parts, and pinched foreign materials.
Is the inspection result normal?
YES
GO TO 3.
NO
Repair or replace the malfunctioning parts.
- Check that back door assembly is installed normally.
- CHECK ENCODER SIGNAL
- Select "AUTOMATIC BACK DOOR CONTROL MODULE" using CONSULT.
- Select "SPINDLE LH ENCODER A" and "SPINDLE LH ENCODER B" in "DATA MONITOR" mode.
- Check that the function operates normally according to the following conditions.
Monitor item
Condition
Status
SPINDLE LH ENCODER A
Back door
Moving (auto or manual)
HI <=> LO
When stopped
HI or LO
SPINDLE LH ENCODER B
Moving (auto or manual)
HI <=> LO
When stopped
HI or LO
Is the inspection result normal?
YES
Replace automatic back door control module. Refer to Removal and Installation .
NO
GO TO 4.
- CHECK ENCODER POWER SUPPLY
- Turn ignition switch OFF.
- Disconnect spindle unit LH connector.
- Turn ignition switch ON.
- Check voltage between spindle unit LH harness connector and ground.
(+)
(-)
Voltage
(Approx.)
Spindle unit LH
Connector
Terminal
B70
8
Ground
Battery voltage
Is the inspection result normal?
YES
GO TO 6.
NO
GO TO 5.
- CHECK ENCODER POWER SUPPLY CIRCUIT
- Turn ignition switch OFF.
- Disconnect automatic back door control module connector.
- Check continuity between automatic back door control module harness connector and spindle unit LH harness connector.
Automatic back door control module
Spindle unit LH
Continuity
Connector
Terminal
Connector
Terminal
B55
19
B70
8
Yes
- Check continuity between automatic back door control module harness connector and ground.
Automatic back door control module
Ground
Continuity
Connector
Terminal
B55
19
No
Is the inspection result normal?
YES
Replace automatic back door control module. Refer to Removal and Installation .
NO
Repair or replace harness.
- CHECK ENCODER SIGNAL CIRCUITS
- Turn ignition switch OFF.
- Disconnect automatic back door control module connector.
- Check continuity between automatic back door control module harness connector and spindle unit LH harness connector.
Automatic back door control module
Spindle unit LH
Continuity
Connector
Terminal
Connector
Terminal
B55
6
B70
3
Yes
7
10
- Check continuity between automatic back door control module harness connector and ground.
Automatic back door control module
Ground
Continuity
Connector
Terminal
B55
6
No
7
Is the inspection result normal?
YES
GO TO 7.
NO
Repair or replace harness.
- CHECK ENCODER GROUND CIRCUIT
- Connect automatic back door control module and spindle unit LH connector.
- Check continuity between automatic back door control module harness connector and ground.
Automatic back door control module
Ground
Voltage
(Approx.)
Connector
Terminal
B55
21
0 V
Is the inspection result normal?
YES
Replace spindle unit LH. Refer to Removal and Installation .
NO
Repair or replace harness.