LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different car >> Section 608 (Heater & Air Conditioning Control System) >> Symptom Diagnosis >> Rear Automatic Air Conditioning System >> Diagnosis Chart By Symptom

Diagnosis Chart By Symptom

WARNING: This page is about a different car, the 2020 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
NOTE:
  • Perform the self-diagnoses with CONSULT before performing the symptom diagnosis. If DTC is detected, perform the corresponding diagnosis.
  • The following table is based on the condition that front automatic air conditioning system operates normally.

Symptom

Corresponding malfunction part

Reference

  • Rear air conditioning cannot be controlled by front A/C control.
  • Operation status of rear air conditioning is not indicated on front A/C control display.

A/C auto amp.

Replace A/C auto amp. Refer to Removal and Installation .

Rear air conditioning cannot be controlled by rear air control.

Operation status of rear air conditioning is indicated on rear air control display.

Communication signal (rear air control --> A/C auto amp.)

Diagnosis Procedure

Operation status of rear air conditioning is not indicated on rear air control display.

Communication signal (A/C auto amp. --> rear air control)

Diagnosis Procedure

Rear air control power supply circuit

Diagnosis Procedure

  • Air outlet does not change.
  • Mode door motor (rear) does not operate normally.
  • Circuit between mode door motor (rear) and A/C auto amp.
  • Mode door motor (rear) control linkage
  • Mode door motor (rear)
  • A/C auto amp.

Diagnosis Procedure

  • Discharge air temperature does not change.
  • Air mix door motor (rear) does not operate normally.
  • Circuit between air mix door motor (rear) and A/C auto amp.
  • Air mix door motor (rear) installation condition
  • Air mix door motor (rear)
  • A/C auto amp.

Diagnosis Procedure

Rear blower motor operation is malfunctioning.

  • Power supply system of rear blower motor
  • Circuit between rear blower motor and A/C auto amp.
  • Rear blower motor
  • A/C auto amp.

Diagnosis Procedure

  • Insufficient cooling.
  • No cool air comes out. (Air flow volume is normal.)
  • A/C auto amp.
  • Refrigerant cycle
  • Air leakage from each duct
  • Temperature setting trimmer (rear)

Diagnosis Procedure 

  • Insufficient heating.
  • No warm air comes out. (Air flow volume is normal.)
  • Air leakage from each duct
  • Temperature setting trimmer (rear)

Diagnosis Procedure 

Noise is heard when rear blower motor operates.

  • Mixing any foreign object in rear blower motor
  • Rear blower motor fan breakage
  • Rear blower motor rotation inferiority

Component Inspection (Rear Blower Motor)