LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different car >> Section 501 (Engine Control System (DTC/Circuit Diagnosis) (2 Of 3)) >> DTC/Circuit Diagnosis >> DTC P0157: Ho2S2 >> DTC Diagnosis Procedure

DTC Diagnosis Procedure

WARNING: This page is about a different car, the 2019 Nissan NV3500 HD, 2019 Nissan NV2500 HD, and 2019 Nissan NV1500. However, it is still accessible from the selected car via links, so may be relevant.
  1. CLEAR THE MIXTURE RATIO SELF-LEARNING VALUE 
    1. Clear the mixture ratio self-learning value. Refer to Description .
    2. Run engine for at least 10 minutes at idle speed.

    Is the 1st trip DTC P0171 or P0174 detected? Is it difficult to start engine?

    YES

    Perform trouble diagnosis for DTC P0171 or P0174. Refer to DTC Description  or DTC Description .

    NO

    GO TO 2.

  2. CHECK HO2S2 GROUND CIRCUIT 
    1. Turn ignition switch OFF.
    2. Disconnect heated oxygen sensor 2 (HO2S2) harness connector.
    3. Disconnect ECM harness connector.
    4. Check the continuity between HO2S2 harness connector and ECM harness connector.

      +

      -

      Continuity

      HO2S2

      ECM

      Bank

      Connector

      Terminal

      Connector

      Terminal

      2

      F12

      4

      F54

      35

      Existed

    5. Also check harness for short to power.

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    Repair or replace error-detected parts.

  3. CHECK HO2S2 INPUT SIGNAL CIRCUIT 
    1. Check the continuity between HO2S2 harness connector and ECM harness connector.

      +

      -

      Continuity

      HO2S2

      ECM

      Bank

      Connector

      Terminal

      Connector

      Terminal

      2

      F12

      1

      F54

      32

      Existed

    2. Check the continuity between HO2S2 harness connector and ground, or ECM harness connector and ground.

      +

      -

      Continuity

      HO2S2

      Bank

      Connector

      Terminal

      2

      F12

      1

      Ground

      Not existed

      +

      -

      Continuity

      ECM

      Bank

      Connector

      Terminal

      2

      F54

      32

      Ground

      Not existed

    3. Also check harness for short to power.

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    Repair or replace error-detected parts.

  4. CHECK HEATED OXYGEN SENSOR 2 

    Check the heated oxygen sensor 2. Refer to Component Inspection .

    Is the inspection result normal?

    YES

    Check intermittent incident. Refer to Intermittent Incident .

    NO

    GO TO 5.

  5. REPLACE HEATED OXYGEN SENSOR 2 

    Replace heated oxygen sensor 2. Refer to Exploded View .

    CAUTION:
    • Discard any sensor which has been dropped from a height of more than 0.5 m (19.7 in) onto a hard surface such as a concrete floor; use a new one.
    • Before installing new sensor, clean exhaust system threads using Oxygen Sensor Thread Cleaner [commercial service tool (J-43897-18 or J43897-12)] and approved Anti-seize Lubricant (commercial service tool).

    INSPECTION END