LEMON Manuals: Even more car manuals for everyone
Home >> Nissan-Datsun >> 2021 >> NV2500 HD S >> Repair and Diagnosis >> External Pages >> Different car >> Section 421 (Heater & Air Conditioning Control System (DTC/Circuit Diagnosis)) >> DTC/Circuit Diagnosis >> Rear Blower Motor >> Diagnosis Procedure >> REAR BLOWER MOTOR 2 (For Mexico)

REAR BLOWER MOTOR 2 (For Mexico)

WARNING: This page is about a different car, the 2019 Infiniti QX60. However, it is still accessible from the selected car via links, so may be relevant.
  1. CHECK FUSE 

    Check 20A fuse [No. 71, located in the fuse block (J/B)].

    Is the inspection result normal?

    YES

    GO TO 2.

    NO

    Replace fuse after repairing the affected circuit.

  2. CHECK POWER SUPPLY FOR REAR BLOWER MOTOR 2 
    1. Turn ignition switch ON.
    2. Check voltage between rear blower motor 2 harness connector and ground.

      (+)

      (-)

      Voltage

      (Approx.)

      Rear blower motor 2

      Connector

      Terminal

      B134

      1

      Ground

      Battery voltage

    Is the inspection result normal?

    YES

    GO TO 3.

    NO

    GO TO 7.

  3. CHECK POWER SUPPLY FOR REAR BLOWER MOTOR RESISTOR 2 

    Check voltage between rear blower motor resistor 2 harness connector and ground.

    (+)

    (-)

    Voltage

    (Approx.)

    Rear blower motor resistor 2

    Connector

    Terminal

    B133

    1

    Ground

    Battery voltage

    Is the inspection result normal?

    YES

    GO TO 4.

    NO

    GO TO 8.

  4. CHECK BLOWER MOTOR CONTROL SIGNAL 
    1. Turn mode control to VENT.
    2. Turn fan control to 1st speed.
    3. Check voltage between rear blower motor resistor 2 harness connector and ground.

      (+)

      (-)

      Voltage

      (Approx.)

      Rear blower motor resistor 2

      Connector

      Terminal

      B133

      2

      Ground

      2.5 V

    Is the inspection result normal?

    YES

    GO TO 5.

    NO

    Less than approximately 2.5 V: GO TO 9.

    NO

    More than approximately 10 V: Replace A/C auto amp.

  5. CHECK REAR BLOWER MOTOR RESISTOR 2 GROUND CIRCUIT 
    1. Disconnect rear blower motor resistor 2 connector.
    2. Check continuity between rear blower motor resistor 2 harness connector and ground.

      Rear blower motor resistor 2

      --

      Continuity

      Connector

      Terminal

      B133

      3

      Ground

      Yes

    Is the inspection result normal?

    YES

    GO TO 6.

    NO

    Repair harness or connector.

  6. CHECK BLOWER MOTOR FEEDBACK SIGNAL 
    1. Reconnect rear blower motor resistor 2 connector.
    2. Turn ignition switch ON.
    3. Turn fan control to 1st speed.
    4. Check voltage between A/C auto amp. harness connector and ground.

      (+)

      (-)

      Condition

      Voltage

      (Approx.)

      A/C auto amp.

      Connector

      Terminal

      M50

      32

      Ground

      Blower speed: 1st

      (Blower motor operating)

      10 V

    Is the inspection result normal?

    YES

    Replace A/C auto amp.

    NO

    Repair harness or connector.

  7. CHECK POWER VOLTAGE OF REAR BLOWER MOTOR RELAY 
    1. Turn ignition switch OFF.
    2. Remove blower relay.
    3. Turn ignition switch ON.
    4. Check voltage between rear blower motor relay connector terminals and ground.

      (+)

      (-)

      Voltage

      (Approx.)

      Rear blower motor relay

      Connector

      Terminal

      M108

      1

      Ground

      Battery voltage

      6

    Is the inspection result normal

    YES

    . Refer to Component Inspection (Rear Blower Motor Relay) .

    NO

    .

  8. CHECK CIRCUIT CONTINUITY BETWEEN BLOWER MOTOR AND REAR BLOWER MOTOR RESISTOR 2 
    1. Turn ignition switch OFF.
    2. Disconnect rear blower motor resistor 2 connector.
    3. Check continuity between rear blower motor 2 harness connector and rear blower motor resistor 2 harness connector.

      Rear blower motor 2

      Rear blower motor resistor 2

      Continuity

      Connector

      Terminal

      Connector

      Terminal

      B134

      2

      B133

      1

      Yes

    Is the inspection result normal?

    YES

    Replace rear blower motor 2.

    NO

    Repair harness or connector.

  9. CHECK REAR BLOWER MOTOR RESISTOR 2 

    Check rear blower motor resistor 2. Refer to Component Inspection (Rear Blower Motor Resistor) .

    Is the inspection result normal?

    YES

    Replace A/C auto amp.

    NO

    Replace rear blower motor resistor 2.