Detailed Flow
- OBTAIN INFORMATION ABOUT SYMPTOM
Interview the customer to obtain as much information as possible about the conditions and environment under which the malfunction occurred.
GO TO 2.
- CHECK SYMPTOM
- Check the symptom based on the information obtained from the customer.
- Check if any other malfunctions are present.
GO TO 3.
- CHECK ON BOARD DIAGNOSIS OPERATION
Check that the on board diagnosis function operates. Refer to On Board Diagnosis Function .
Is the inspection result normal?
YES
GO TO 4.
NO
GO TO 6.
- CHECK CONSULT SELF-DIAGNOSIS RESULTS
- Perform "Self Diagnostic Result". Refer to DTC Index .
- When DTC is detected, follow the instructions below:
- Record DTC and Freeze Frame Data.
Is the inspection result normal?
YES
GO TO 5.
NO
GO TO 10.
- NARROW DOWN THE MALFUNCTIONING PARTS BY SYMPTOM DIAGNOSIS
Perform symptom diagnosis and narrow down the malfunctioning parts.
GO TO 10.
- CHECK METER CONTROL SWITCH SIGNAL CIRCUIT
Check meter control switch signal circuit. Refer to Diagnosis Procedure .
Is the inspection result normal?
YES
GO TO 7.
NO
GO TO 10.
- CHECK METER CONTROL SWITCH
Check meter control switch. Refer to Component Inspection .
Is the inspection result normal?
YES
GO TO 8.
NO
GO TO 10.
- CHECK COMBINATION METER POWER SUPPLY AND GROUND CIRCUITS
Check combination meter power supply and ground circuits. Refer to Diagnosis Procedure .
Is the inspection result normal?
YES
GO TO 9.
NO
GO TO 10.
- REPLACE COMBINATION METER
Replace combination meter. Refer to Removal and Installation .
GO TO 11.
- REPAIR OR REPLACE MALFUNCTIONING PARTS
Repair or replace the malfunctioning parts.
NOTE: If DTC is displayed, erase DTC after repairing or replacing malfunctioning parts.GO TO 11.
- FINAL CHECK
Check that the combination meter operates normally.
Is the inspection result normal?
YES
Inspection End.
NO
GO TO 2.