Detailed Flow
- INTERVIEW FOR MALFUNCTION
Interview the symptom to the customer.
GO TO 2 .
- SYMPTOM CHECK
Check the symptom from the customer's information. Check that any symptom occurs other than the interviewed symptom.
Insufficient cooling/heating
GO TO 3 .
Refrigerant leakage
GO TO 6 .
NO
GO TO 7 .
- CONTROL SYSTEM DIAGNOSIS
Perform the system diagnosis for the A/C control system. Refer to Work Flow (with auto A/C) or Work Flow (with manual A/C).
Is A/C control system normal?
YES
GO TO 4 .
NO
GO TO 8 .
- PERFORMANCE TEST
Perform the performance test. Check the operation of each part. Refer to Inspection .
GO TO 5 .
- TROUBLE DIAGNOSIS FOR UNUSUAL PRESSURE
Diagnose using a manifold gauge whenever system's high and/or low side pressure(s) is/are unusual. Specify the malfunctioning part. Refer to Trouble Diagnoses for Abnormal Pressure .
Low refrigerant charge
GO TO 6 .
Except above
GO TO 8 .
- CHECK REFRIGERANT FOR LEAKAGES
Check refrigerant for leakages. Specify the malfunctioning part. Refer to Leak Test .
GO TO 8 .
- TROUBLE DIAGNOSIS FOR NOISE
Perform trouble diagnosis for noise. Specify the malfunctioning part. Refer to Symptom Table .
GO TO 8 .
- MALFUNCTIONING PART REPAIR
Repair or replace the malfunctioning part.
GO TO 9 .
- REPAIR CHECK (OPERATION CHECK)
Check the operation of each part.
Does it operate normally?
YES
Inspection End.
NO
GO TO 2 .