DTC Detection Logic
WARNING: This page is about a different car, the 2018 Nissan Titan XD. However, it is still accessible from the selected car via links, so may be relevant.
The ECM detected a mismatch between the engine's electrical system voltage and the intake NOx sensor voltage rating.
|
DTC |
CONSULT screen terms (Trouble diagnosis content) |
DTC detection condition |
|
|
P2204-00 |
NOX SENSOR BANK1 SENSOR1 |
Diagnosis condition |
This diagnostic runs when the ignition switch is ON or when the engine is running. |
|
Signal (terminal) |
Intake NOx sensor signal. |
||
|
Threshold |
Engine electrical system voltage does not match NOx sensor voltage rating. |
||
|
Diagnosis delay time |
- |
||