Diagnosis Procedure
- CHECK DTC PRIORITY
- Turn ignition switch ON.
- Connect CONSULT and check for other existing "ENGINE" diagnostic trouble codes.
If DTC P21CA is present, perform the confirmation procedure (trouble diagnosis) for this other DTC first.
Is applicable DTC detected?
YES
Perform diagnosis of applicable DTC. Refer to DTC Description .
NO
GO TO 2 .
- CHECK FOR CURRENT DEF PRESSURE SENSOR DTC
Check for DTC P204C current on the CONSULT screen.
Is applicable DTC current?
YES
GO TO 3 .
NO
Refer to Intermittent Incident .
- INSPECT DEF SUPPLY PUMP ASSEMBLY AND ELECTRICAL CONNECTIONS
- Turn ignition switch OFF.
- Disconnect the DEF supply pump assembly connector.
- Inspect connector and pins for the following:
- Loose connector.
- Corroded pins.
- Bent or broken pins.
- Pushed back or expanded pins.
- Moisture in or on the connector.
- Missing or damaged connector seals.
- Dirt or debris on or in the connector pins.
- Connector shell broken.
- Wire insulation damage.
- Damaged connector locking tab.
Is the inspection result normal?
YES
GO TO 4 .
NO
Repair or replace error-detected parts.
- CHECK DEF PRESSURE SENSOR POWER SUPPLY CIRCUITS
- Turn ignition switch ON.
- Check the voltage between DEF supply pump assembly connector sensor supply voltage and return circuit terminals.
DEF supply pump assembly
Voltage (V)
(Approx.)
Connector
Terminal (+)
Terminal (-)
C204
13
11
Approx. 5
Is the inspection result normal?
YES
GO TO 5 .
NO
GO TO 7 .
- CHECK THE CIRCUIT RESPONSE
- Turn ignition switch OFF.
- Connect a jumper wire between DEF supply pump assembly 5V supply terminal 13 and signal circuit terminal 12.
- Turn ignition switch ON and wait 30 seconds.
- Connect CONSULT and check for current "ENGINE" diagnostic trouble codes.
Did DTC P204D become current and P204C become past?
YES
GO TO 6 .
NO
GO TO 7 .
- CHECK THE CIRCUIT RESPONSE
- Turn ignition switch OFF.
- Disconnect the jumper wire.
- Reconnect the DEF supply pump assembly connector.
- Turn ignition switch ON and wait 30 seconds.
- Connect CONSULT and check for current ENGINE diagnostic trouble codes.
Did P203C DTC become current?
YES
A damaged tank level sensor has been detected. Replace the after treatment DEF supply pump assembly. Refer to Exploded View .
NO
The removal and installation of the connector corrected the issue. Repair complete.
- INSPECT DEF CONTROL MODULE AND ELECTRICAL CONNECTIONS
- Disconnect the DEF control module.
- Inspect both connectors and pins for the following:
- Loose connector.
- Corroded pins.
- Bent or broken pins.
- Pushed back or expanded pins.
- Moisture in or on the connector.
- Missing or damaged connector seals.
- Dirt or debris on or in the connector pins.
- Connector shell broken.
- Wire insulation damage.
- Damaged connector locking tab.
Is the inspection result normal?
YES
GO TO 8 .
NO
Repair or replace error-detected parts.
- CHECK TANK PRESSURE SENSOR POWER CIRCUIT FOR OPEN
Check the 5 volt power circuit for continuity between the DEF control module and the DEF supply pump assembly.
DEF control module
DEF supply pump assembly
Continuity
Connector
Terminal
Connector
Terminal
C205
27
C204
13
Yes
Is the inspection result normal?
YES
GO TO 9 .
NO
Repair open circuit in harness or connectors.
- CHECK TANK PRESSURE SENSOR SIGNAL CIRCUIT FOR OPEN
Check the signal circuit for continuity between the DEF control module and the DEF supply pump assembly.
DEF control module
DEF supply pump assembly
Continuity
Connector
Terminal
Connector
Terminal
C205
25
C204
12
Yes
Is the inspection result normal?
YES
GO TO 10 .
NO
Repair open circuit in harness or connectors.
- CHECK TANK PRESSURE SENSOR SIGNAL CIRCUIT FOR SHORT TO OTHER CIRCUITS
Check the continuity between DEF tank pressure sensor signal and all other circuits at the DEF control module harness connector.
DEF control module
Continuity
Connector
Terminal
Terminal
C205
25
All others
No
Is the inspection result normal?
YES
GO TO 11 .
NO
Repair short circuit in harness or connectors.
- CHECK TANK PRESSURE SENSOR SIGNAL CIRCUIT FOR SHORT TO GROUND
Check the continuity between DEF tank pressure sensor signal circuit and ground.
DEF control module
Ground
Continuity
Connector
Terminal
C205
25
-
No
Is the inspection result normal?
YES
GO TO 12 .
NO
Repair or replace harness for a short to ground.
- CHECK FOR CURRENT DTC
- Connect all harness connectors.
- Turn ignition switch ON and wait 30 seconds.
- Connect CONSULT and check for current "ENGINE" diagnostic trouble codes.
Is P204C DTC current?
YES
Replace DEF control module. Refer to Exploded View .
NO
The removal and installation of the connector corrected the issue.