Diagnostic Test
- CHECK G SENSOR SIGNAL
With CONSULT
- Park the vehicle on a level surface.
- Turn ignition switch ON.
- Select "Data Monitor" in "TRANSMISSION".
- Select "G SEN SLOPE".
- Swing the vehicle and check if value varies between - 40.45% and 40.45%.
Monitor item Condition Standard G SEN SLOPE Flat road 0% Uphill Positive value (Maximum 40.45%) Downhill Negative value (Minimum - 40.45%)
Is the inspection result normal?
YES
GO TO STEP 2 .
NO
GO TO STEP 3 .
- G SENSOR CALIBRATION (PART 1)
With CONSULT
- Select "Self Diagnostic Results" in "TRANSMISSION".
- Touch "Erase".
Perform "G SENSOR CALIBRATION". Refer to WORK PROCEDURE .
- CHECK G SENSOR
- Remove G sensor. REMOVAL AND INSTALLATION .
- Connect the all connectors.
- Turn ignition switch ON.
- Check voltage between TCM harness connector terminal and ground.
: Direction of gravitational force + - Condition Voltage
(Approx.)TCM Connector Terminal F44 14 Ground Vertical (- 1G) (A) 1.17 V Horizontal (B) 2.5 V Vertical (1G) (C) 3.83 V
Is the inspection result normal?
YES
GO TO STEP 4 .
NO
Replace G sensor.REMOVAL AND INSTALLATION .
- G SENSOR CALIBRATION (PART 2)
With CONSULT
- Install G sensor. REMOVAL AND INSTALLATION .
- Select "Self Diagnostic Results" in "TRANSMISSION".
- Touch "Erase".
Perform "G SENSOR CALIBRATION". Refer to WORK PROCEDURE .