Diagnosis Procedure
- CHECK VDC OFF SWITCH
Perform the trouble diagnosis for VDC OFF switch. Refer to "DIAGNOSIS PROCEDURE ".
Is the inspection result normal?
YES: GO TO 2.
NO: Check VDC OFF switch. Refer to "DIAGNOSIS PROCEDURE ".
- CHECK SELF-DIAGNOSIS
Perform ABS actuator and electric unit (control unit) self-diagnosis.
Is the inspection result normal?
YES: GO TO 3.
NO: Check items displayed by self-diagnosis.
- CHECK COMBINATION METER
Check the indication and operation of combination meter are normal. Refer to "DIAGNOSIS DESCRIPTION ".
Is the inspection result normal?
YES: Replace ABS actuator and electric unit (control unit).
NO: Repair or replace combination meter.