Diagnosis Procedure
- CHECK VDC OFF SWITCH
Check VDC OFF switch. Refer to "COMPONENT INSPECTION ".
Is the inspection result normal?
YES: GO TO 2.
NO: Replace VDC OFF switch.
- CHECK VDC OFF SWITCH HARNESS
- Disconnect ABS actuator and electric unit (control unit) connector.
- Disconnect VDC OFF switch connector.
- Check the continuity between VDC OFF switch harness connector and ABS actuator and electric unit (control unit) harness connector.TERMINALS CONTINUITY REFERENCE
ABS actuator and electric unit (control unit) VDC OFF switch Continuity Connector Terminal Connector Terminal E36 22 M5 1 Existed - Check the continuity between ABS actuator and electric unit (control unit) harness connector and ground.TERMINALS CONTINUITY REFERENCE
ABS actuator and electric unit (control unit) - Continuity Connector Terminal E36 22 Ground Not existed - Check the continuity between VDC OFF switch harness connector and ground.
TERMINALS CONTINUITY REFERENCEVDC OFF switch - Continuity Connector Terminal M5 2 Ground Existed Is the inspection result normal?
YES: GO TO 3.
NO: Repair or replace damaged parts.
- CHECK COMBINATION METER
- Connect ABS actuator and electric unit (control unit) connector.
- Connect VDC OFF switch connector.
- Check the indication and operation of combination meter are normal. Refer to "DIAGNOSIS DESCRIPTION ".
Is the inspection result normal?
YES: INSPECTION END
NO: Repair or replace combination meter.