Turn Signal Lamp Does Not Operate
- BULB INSPECTION
Check each turn signal lamp bulb to make sure correct bulbs are installed.
OK or NG
- OK : GO TO 2.
- NG : Replace bulb.
- INSPECTION 1 BETWEEN COMBINATION SWITCH AND BCM
Select "BCM" on CONSULT-II. Carry out BCM C/U self-diagnosis.
Displayed results of self-diagnosis
- Diagnosis system 1 - 5 : Combination switch system malfunction.
Refer to, "COMBINATION SWITCH INSPECTION ACCORDING TO SELF - DIAGNOSTIC RESULTS ".
- No malfunction detected : GO TO 3.
- Diagnosis system 1 - 5 : Combination switch system malfunction.
- INSPECTION 2 BETWEEN COMBINATION SWITCH AND BCM
Select "BCM" on CONSULT-II. With "FLASHER" data monitor, check that "TURN SIGNAL R" and "TURN SIGNAL L" turn ON-OFF according to operation of turn signal switch.
OK or NG
- OK : GO TO 4.
- NG : Replace lighting switch. Refer to, "REMOVAL AND INSTALLATION ".
- INSPECTION 1 BETWEEN BCM AND TURN SIGNAL LAMPS
- Select "BCM" on CONSULT-II. Select "FLASHER" active test.
- Check that "FLASHER RIGHT" and "FLASHER LEFT" operate.
OK or NG
- OK : Replace BCM.
- NG : GO TO 5.
- INSPECTION 2 BETWEEN BCM AND TURN SIGNAL LAMPS
- Disconnect BCM connector and all turn signal lamp connectors.
- Check continuity between harness connectors of BCM and body ground.
OK or NG
- OK : Replace BCM.
- NG : Check for short circuit in harnesses between BCM and each turn signal and repair as necessary.