ACTUATOR TEST DESCRIPTION
| Item No. | Item name [Scan tool (M.U.T.-IIISE) indication] | Test item [Scan tool (M.U.T.-IIISE) indication] | Test contents | ||
|---|---|---|---|---|---|
| 1 | Mirror indicator | OFF | Turns on/off the blind spot warning indicator light on door mirror. | ||
| ON | |||||
| 2(1) | BSW indicator | OFF | Makes the blind spot warning indicator light on the combination meter go out or illuminate. | ||
| ON | |||||
| 3(1) | Meter indication (BSW status) | OFF | Modifies the BSW status forcibly. | ||
| No request | |||||
| Temporary fail | |||||
| Fail | |||||
| Blockage | |||||
| 4(1) | BSW buzzer | OFF | Stops the BSW tone alarm in the combination meter. | ||
| Warning buzzer | Sounds the BWS warning tone alarm in the combination meter. | ||||
| 5(1) | Meter indication (RCTA warning) | No request | Erases the RCTA warning indication on the combination meter. | ||
| Both warning | Displays RCTA warning indication on the combination meter. | ||||
| 6(1) | RCTA buzzer | OFF | Stops the RCTA tone alarm in the combination meter. | ||
| Warning buzzer | Sounds the RCTA warning tone alarm in the combination meter. | ||||
| 7 | BSW ON/OFF setting | No request | Change the BSW setting to reset | ||
| OFF | Change the BSW setting to OFF | ||||
| ON | Change the BSW setting to ON | ||||
|