Home >> Mitsubishi >> 2015 >> Outlander GT >> Repair and Diagnosis >> Accessories & Equipment >> Gauges & Instrument Panels >> Combination Meter On-Vehicle Service - With Diagnostics >> Combination Meters Diagnostic >> Symptom Procedures >> Inspection Procedure 8: Fuel gauge does not work (the other meters work) >> Diagnosis

Inspection Procedure 8: Fuel gauge does not work (the other meters work): Diagnosis

  1. STEP 1. Using scan tool (M.U.T.-III), read the combination meter diagnostic trouble code. 
    CAUTION: To prevent damage to scan tool (M.U.T.-III), always turn the ignition switch to the "LOCK" (OFF) position before connecting or disconnecting scan tool (M.U.T.-III).
    1. Connect scan tool (M.U.T.-III). Refer to "HOW TO CONNECT THE SCAN TOOL (M.U.T.-III) ."
    2. Turn the ignition switch from "LOCK" (OFF) position to "ON" position.
    3. Check if DTC No. B1201 is stored.

    Q: Is DTC No. B1201 stored? 

    1. YES:  Follow the relevant DTC procedure (Refer to DIAGNOSTIC TROUBLE CODE CHART  ).
    2. NO:  Go to Step 2.
  2. STEP 2. Fuel pump module and fuel level sensor (sub) < AWD > check 

    Check the fuel pump module and fuel level sensor (sub) < AWD >. Refer to < FWD >  .

    Q: Is the check result normal? 

    1. YES:  Go to Step 3.
    2. NO:  Replace the fuel pump module and fuel level sensor (sub) < AWD >.
  3. STEP 3. Using scan tool (M.U.T.-III), check data list 

    Q: Is the check result normal? 

    1. YES:  Go to Step 4.
    2. NO:  Replace the combination meter, and then go to  Step 5.
  4. STEP 4. Using scan tool (M.U.T.-III), check actuator test 

    Q: Is the check result normal? 

    1. YES:  Go to Step 5.
    2. NO:  Replace the combination meter, and then go to Step 5
  5. STEP 5. Retest the system. 

    Check that the fuel gauge works normally.

    Q: Is the check result normal? 

    1. YES:  The procedure is complete. (If no malfunctions are found in all steps, an intermittent malfunction is suspected. Refer to HOW TO COPE WITH INTERMITTENT MALFUNCTION ).
    2. NO:  Replace the combination meter.