>> A << Differential Carrier Assembly Installation
WARNING: This page is about a different variant/trim than selected.
- Check that the length of the electronic control coupling stud bolt (A) is within the standard value range.
Standard value: 22.3 - 25.1 mm (0.88 - 0.99 inch)
- If the length exceeds the standard value, replace the stud bolt.
Specified torque: 15 ± 3 N.m (11 ± 2 ft-lb)
NOTE: When replacing the stud bolts, always clean the stud bolt threaded holes.