Power Liftgate Control Unit Terminal Inspection
WARNING: This page is about a different car, the 2014 Mitsubishi Outlander. However, it is still accessible from the selected car via links, so may be relevant.
| Terminal number | Terminal code | Check items | Check conditions | Normal conditions |
|---|---|---|---|---|
| 1 | BAT1 | Battery power supply | Always | Battery voltage |
| 2 | GND1 | Ground | Always | 1 V or less |
| 3 | BUP2 | Battery power supply | Always | System voltage |
| 4 | FULL | Liftgate latch (full latch switch) input | Power liftgate: Overrun position | 1 V or less |
| 5 | IG12 | Ignition switch power supply | Ignition switch: ON | System voltage |
| 6 | GOPN | Input from liftgate lock release handle | Liftgate lock release handle: ON | 1 V or less |
| 7 | CANH | CAN H | - | - |
| 8 | CANL | CAN L | - | - |
| 9 | GCLS | Input from power liftgate close switch | Power liftgate close switch: ON | 1 V or less |
| 10 | - | - | - | - |
| 11 | PLCL | Liftgate latch (engagement) output | During liftgate latch fully close operation | 12 V |
| 12 | PLOP | Liftgate latch (release) output | During liftgate latch claw release operation | 12 V |
| 13 | BZ+ | Tone alarm (+) output | Tone alarm is sounding | 0 to 12 V (pulse signal) |
| 14 | - | - | - | - |
| 15 | NTL | Liftgate latch (neutral switch) input | Liftgate latch: Open side (fully open normal status) | 1 V or less |
| 16 | - | - | - | - |
| 17 | HARF | Liftgate latch (half latch switch) input | Power liftgate: Open position | 1 V or less |
| 18 | - | - | - | - |
| 19 | LTH | Liftgate latch (door-ajar switch) input | Power liftgate: Open position | 1 V or less |
| 20 | - | - | - | - |
| 21 | - | - | - | - |
| 22 | MASW | Power liftgate main switch input | Power liftgate main switch: ON | 1 V or less |
| 23 | OPSW | Power liftgate switch input | Power liftgate switch: ON | 1 V or less |
| 24 | TSL | Liftgate sensor left side input | Liftgate sensor left side: ON | 1 V or less |
| 25 | TSG | Liftgate sensor ground | Always | 1 V or less |
| 26 | TSR | Liftgate sensor right side input | Liftgate sensor right side: ON | 1 V or less |