INSPECTION PROCEDURE 9: Blower Motor power supply system: Diagnosis
Required Special Tools:
- MB991223: Harness Set
- MB992006: Extra Fine Probe
- STEP 1. Check blower relay connector C-303 for loose, corroded or damaged terminals, or terminals pushed back in the connector.
Q: Is blower relay connector C-303 in good condition?
YES : Go to Step 2.
NO : Repair or replace the connector. Refer to HARNESS CONNECTOR INSPECTION .
- STEP 2. Check the blower relay continuity.
Follow the table below to check the blower relay for continuity.
BLOWER RELAY CONTINUITY CHECKBattery voltage Tester connection Specified condition Not applied 3 - 4 Open circuit - Connect terminal 1 to the positive battery terminal
- Connect terminal 2 to the negative battery terminal
3 - 4 Less than 2 ohms Q: Is the blower relay in good condition?
YES : Go to Step 3.
NO : Replace the rear window defogger relay.
- STEP 3. Measure the voltage at blower relay connector C-303.
- Disconnect blower relay connector C-303, and measure the voltage at the junction block side.
- Measure the voltage between terminals 1 and ground.
- The measured value should be approximately 12 volts (battery positive voltage).
- Measure the voltage between terminals 4 and ground.
- The measured value should be approximately 12 volts (battery positive voltage).
Q: Is the measured voltage approximately 12 volts?
YES : Go to Step 5.
NO : Go to Step 4.
- STEP 4. Check the wiring harness between blower relay connector C-303 (terminals 1 and 4) and the fusible link (37). NOTE: Also check ETACS-ECU connector C-309 for loose, corroded, or damaged terminals, or terminals pushed back in the connector. If ETACS-ECU connector C-309 is damaged, repair or replace the connector as described in HARNESS CONNECTOR INSPECTION .
Q: Is the wiring harness between blower relay connector C-303 (terminals 1 and 4) and the fusible link (37) in good condition?
YES : It can be assumed that this malfunction is intermittent. Refer to HOW TO COPE WITH INTERMITTENT MALFUNCTIONS .
NO : Repair or replace the wiring harness. Refer to HARNESS CONNECTOR INSPECTION .
- STEP 5. Check blower relay connector C-115 for loose, corroded or damaged terminals, or terminals pushed back in the connector.
Q: Is blower relay connector C-115 in good condition?
YES : Go to Step 6.
NO : Repair or replace the connector. Refer to HARNESS CONNECTOR INSPECTION .
- STEP 6. Check the wiring harness between blower relay connector C-303 (terminal 3) and blower motor connector C-115 (terminal 1). NOTE: Also check ETACS-ECU connector C-315 for loose, corroded, or damaged terminals, or terminals pushed back in the connector. If ETACS-ECU connector C-315 is damaged, repair or replace the connector as described in HARNESS CONNECTOR INSPECTION .
Q: Is the wiring harness between blower relay connector C-303 (terminal 3) and blower motor connector C-115 (terminal 1) in good condition?
YES : It can be assumed that this malfunction is intermittent. Refer to HOW TO COPE WITH INTERMITTENT MALFUNCTIONS .
NO : Repair or replace the wiring harness. Refer to HARNESS CONNECTOR INSPECTION .