INSPECTION PROCEDURE 6: Door does not Open or Close Completely: Diagnosis
- STEP 1. Check the door hinge position.
Q: Is the door hinge position correct?
- YES: Go to Step 2.
- NO: Adjust the door hinge position. Refer to DOOR FIT ADJUSTMENT . Then go to Step 4.
- STEP 2. Check the door.
Q: Is the door in good condition?
- YES: Go to Step 3.
- NO: Repair or replace door, then go to Step 4.
- STEP 3. Check the grease.
Q: Is the door check or door hinge grease sufficient?
- YES: Go to Step 4.
- NO: Apply the grease, then go to Step 4.
- STEP 4. Retest the system.
Q: Does the door open and close normally?
- YES: The procedure is complete.
- NO: Return to Step 1.