Home >> Mitsubishi >> 2010 >> Lancer ES, Standard >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating, Air Conditioning And Ventilation -- Lancer >> Manual A/C Diagnosis >> Symptom Procedures >> INSPECTION PROCEDURE 10: Blower Motor power supply system >> Diagnosis

INSPECTION PROCEDURE 10: Blower Motor power supply system: Diagnosis

Required Special Tools: 

  1. STEP 1. Check blower relay connector C-303 for loose, corroded or damaged terminals, or terminals pushed back in the connector. 

    Q: Is blower relay connector C-303 in good condition? 

  2. STEP 2. Check the blower relay continuity. 

    Follow the table below to check the blower relay for continuity.

    BATTERY VOLTAGE SPECIFICATION

    Battery voltage Tester connection Specified condition
    Not applied 3 - 4 Open circuit
    • Connect terminal 1 to the positive battery terminal
    • Connect terminal 2 to the negative battery terminal
    3 - 4 Less than 2 ohms

    Q: Is the blower relay in good condition? 

    • YES:  Go to Step 3.
    • NO:  Replace the rear window defogger relay.
      Fig 1: Identifying Blower Relay
      G06670689Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  3. STEP 3. Measure the voltage at blower relay connector C-303. 
    1. Disconnect blower relay connector C-303, and measure the voltage at the junction block side.
    2. Measure the voltage between terminals 1 and ground.
      • The measured value should be approximately 12 volts (battery positive voltage).
        Fig 2: Measuring Voltage Between Terminals 1 And Ground
        G06670690Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
    3. Measure the voltage between terminals 4 and ground.
      • The measured value should be approximately 12 volts (battery positive voltage).

        Q: Is the measured voltage approximately 12 volts? 

        • YES:  Go to Step  5.
        • NO:  Go to Step 4.
          Fig 3: Measuring Voltage Between Terminals 4 And Ground
          G06670691Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.
  4. STEP 4. Check the wiring harness between blower relay connector C-303 (terminals 1 and 4) and the fusible link (37). 
    NOTE: Also check ETACS-ECU connector C-309 for loose, corroded, or damaged terminals, or terminals pushed back in the connector. If ETACS-ECU connector C-309 is damaged, repair or replace the connector as described in HARNESS CONNECTOR INSPECTION .
    • Check the blower relay power supply line for open circuit.

      Q: Is the wiring harness between blower relay connector C-303 (terminals 1 and 4) and the fusible link (37) in good condition? 

  5. STEP 5. Check blower relay connector C-113 for loose, corroded or damaged terminals, or terminals pushed back in the connector. 

    Q: Is blower relay connector C-113 in good condition? 

  6. STEP 6. Check the wiring harness between blower relay connector C-303 (terminal 3) and blower motor connector C-113 (terminal 1). 
    NOTE: Also check ETACS-ECU connector C-315 for loose, corroded, or damaged terminals, or terminals pushed back in the connector. If ETACS-ECU connector C-315 is damaged, repair or replace the connector as described in HARNESS CONNECTOR INSPECTION .
    • Check the blower motor power supply line for open circuit.

      Q: Is the wiring harness between blower relay connector C-303 (terminal 3) and blower motor connector C-113 (terminal 1) in good condition?