LEMON Manuals: Even more car manuals for everyone
Home >> Mitsubishi >> 2010 >> Lancer ES, Standard >> Repair and Diagnosis >> Heating, Ventilation & A/C (HVAC) >> HVAC Control Systems >> Heating, Air Conditioning And Ventilation -- Lancer >> Heater Unit And Blower Assembly >> Inspection >> Air THERMO Sensor Check

Air THERMO Sensor Check

Measure the resistance between the sensor terminals under at least two temperatures. The resistance values should meet the values shown.

NOTE: The temperature should be within the shown range.
Fig 1: Air Thermo Sensor Temperature Graph
G06670714Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.