Ignition Switch Continuity Check: Notes
With the ignition switch mounted to the vehicle, disconnect and check the ignition switch connection connector.
TERMINAL NORMAL CONDITION CHART
| Ignition key position | Terminal number | Normal condition |
|---|---|---|
| LOCK | 1-2, 1-4, 1-5, 1-6 | No continuity |
| ACC | 1-6 | Continuity exists (2 Ω or less) |
| ON | 1-2-4-6 | Continuity exists (2 Ω or less) |
| START | 1-2-5 | Continuity exists (2 Ω or less) |