Home >> Mitsubishi >> 2003 >> Lancer LS >> Repair and Diagnosis >> Electrical >> Gauges >> Gauges & Instrument Panels - Except Evolution >> Symptom Procedures >> Inspection Procedure 6: Combination Meter Does Not Work >> Diagnosis >> Step 4: Measure At Combination Meter Connector C-01 In Order To Check The Battery Circuit Of Power Supply System To The Combination Meter

Step 4: Measure At Combination Meter Connector C-01 In Order To Check The Battery Circuit Of Power Supply System To The Combination Meter

  1. Disconnect combination meter connector C-01, and measure at the wiring harness side.
  2. Turn the ignition switch to "ON" position.
  3. Measure the voltage between terminal No. 9 and ground. See Fig 1 . The measured value should be approximately 12 volts (battery positive voltage).

Does the measured voltage correspond with this range?

Fig 1: Measuring Voltage Between Connector C-01 Terminal No. 9 & Ground
G00377377Courtesy of MITSUBISHI MOTOR SALES OF AMERICA.