61 20 503 Vehicle battery - closed current monitoring
WARNING: This page is about a different car, the 2019 MINI Cooper, 2018 MINI Cooper, 2017 MINI Cooper, 2016 MINI Cooper, and 2015 MINI Cooper. However, it is still accessible from the selected car via links, so may be relevant.
Preliminary work needed:
To access the battery ground lead, perform the preliminary work described in DISCONNECTING BATTERY .
Do not disconnect the battery ground lead!
NOTE:
If several 12V batteries are installed in the vehicle:
Closed-circuit current check is possible on the vehicle battery only.
Closed-circuit current check is possible on the vehicle battery only.
Connect diagnostic system.
Connect the clip-on probe to the battery ground lead of the vehicle battery. The arrow on the clip-on probe must point towards the vehicle battery.
Measure closed-circuit current.